Schematic drawing guide¶
How to draw a schematic sheet that reads at a glance: where the signal enters and leaves, which way power flows, what every part is and why it was chosen. better_erc checks what a schematic does; this page is about how it looks, because a reviewer who cannot read a sheet quickly misses what is wrong on it. The rules that better_erc can check from the drawing are in the check catalogue as DRAW checks, explained on their pages; connectivity hygiene (labels, flags, buses) is WIRE, on its pages.
Most rules are obvious once said: they get the rule and a one-line reason, with the check that measures it. Rules that are not obvious (a KiCad quirk, a house convention with exact values, a setting) get a sketch, the reasons and the source. The tag on those says how firm they are:
- standard: a published standard, convention or tool default says so (the source is named).
- house: what our own sheets do, measured over a private set of 157 production sheets (
N/Msheets, see House style measured), or set by Roman (dated). - new: our recommendation where neither of the above settles it, with the reason.
The sketches use > and < for label and pin direction, * for a junction, ┴ for a ground symbol and ┬ for a supply symbol. KiCad names follow KiCad 10.0; most of it holds for KiCad 8 and 9.
Contents¶
- The sheet: paper, one function per sheet, sections with headings, fill, title block, names
- Notes, boxes and tables: design intent, coloured boxes by kind, tables
- Grid, alignment and spacing: 1.27 mm grid, aligned neighbours, clearance margins, no pin on pin
- Signal flow: left to right, connectors at the edge, symbol orientation, small parts to a rail vertical
- Power and ground: ground down, supplies up, power net names, one symbol per rail per part, the vhrd_power symbols and rail colours, decoupling
- Wires and junctions
- Labels and hierarchy: labels lying on their wire, scopes, sheet pins, buses for groups
- Text: fields, sizes, overlaps
- Parts: unused pins, DNP, multi-unit parts, simulation-only parts and directives
- Colour, print and export
- KiCad settings and shortcuts
- What other tools automate
- House style measured
- Sources
The sheet¶
Paper size: A4 or A3, one size per project¶
A4 or A3 landscape, one size for the whole project; split a function that does not fit an A3. Why: anything bigger does not print readably on a desk printer. DRAW-21
One function per sheet¶
Each sheet holds one function (power input, a regulator group, the MCU, one interface); split it before it gets crowded. Why: a reviewer checks a sheet against one datasheet in one pass. DRAW-18
Sections with a heading, key numbers under it¶
Rule. Group the parts of a sheet into sections by function, with a clear gap between sections (at least 10 mm, more than the gaps inside a section). Each section carries a heading above its top-left corner that names the function (DC-DC 3V3, Low-pass filter, Clamp bus). Under the heading, and only when the section has numbers that matter for review (output voltage, corner frequency, trip current), a small parameter box lists them, one per line. Everything else stays off the sheet or goes in a note box (below).
Why. The heading says what a group of parts is before the reader has to work it out from the parts; the gap says where it ends. The numbers next to the heading are what a reviewer checks first. Text sprinkled everywhere hides both.
Example.
bad: R1 C1 R2 C2 Q1 U1 U2 spaced evenly over the sheet, "fc = 1.6 kHz" next to C1, "Vout 3.3 V" under U2
good: Low-pass filter DC-DC 3V3
┌──────────────┐ ┌──────────────┐
│ fc = 1.6 kHz │ │ Vout = 3.30 V│
└──────────────┘ │ Iout ≤ 1.5 A │
──[R1]──*──[R2]──*── └──────────────┘
C1 C2 [U2] [L1] [C5]
Heading: free text, KiCad default font, 2.54 mm, bold, theme colour, justified left bottom, 2.54 mm above the section's top edge. Bold is the house style, but the checks take any free text at a heading size as a heading. Sections side by side share their heading row, and sections stacked share their left edge (DRAW-45); the gap between any two sections is at least drawing.section_gap (DRAW-44). Parameter box: a KiCad text box, 1.27 mm normal text, stroke 0.1524 mm solid in the Information grey (rgb(110, 110, 110) unless the project gives Information another colour), no fill, right under the heading. Heading and box are a KiCad group, so they move together.
Source. house (Roman, 31 Oct 2026; second review: headings in one row, more gap); EMA and Altium for blocks by function. Check: DRAW-31 (sections without a heading, candidates), DRAW-44, DRAW-45.
The drawing is centred and fills the sheet¶
Centre the circuit with even margins and pick a paper size it fills about half of; nothing touches the frame or the title block. Why: a circuit in one corner prints small and gets lost. DRAW-16, DRAW-17
Title block on every sheet¶
Title, revision, date, paper size and company on every sheet, the revision set once for the project and shown through ${REVISION}. Why: a printed page is read alone. DRAW-19, DRAW-20
VHRD projects use the library drawing sheet (${KICAD_USER_TEMPLATE_DIR}/vhrd_a3.kicad_wks or vhrd_a4, referenced, not copied; the VHRD Default template embeds it). Paper is stored per sheet file, so a project may mix sizes: the index on A2 and the rest on A3 plots one page size per sheet, and vhrd_a3 serves both (corners, title block and frame follow the page, its strip and zones reach A2, ${PAPER} shows the size). It reads the title and date, comment 1 as Drawn, comment 2 as Checked, comment 4 as Status (Draft), and the project variables PRODUCT_NAME, BOARD_NUMBER and VHRD_STAMP (not stamped in the project; the render recipe passes -D VHRD_STAMP="<git describe> · <date>", as KiCad does not expand a variable inside another). Notes about the sheet go in its Information box, not in the comments: the fields are one short line each. Source: house (Roman, 31 Oct 2026; a real board).
Sheet names say the function¶
USB-C input, not Sheet1; the file named after the sheet; an index sheet first in a project of more than three or four sheets. Why: the name is the navigator entry, the PDF bookmark and the page title. DRAW-25
Notes, boxes and tables¶
Notes give the design intent¶
Write down why a part is there and how its value was found: the divider formula with its result, the filter corner, why this TVS. Why: a value without its calculation gets "fixed" in the next revision. DRAW-26
Where it goes: the numbers of one section in its parameter box (sections); the reasoning that spans sections, open questions and instructions in a note box by kind (below), next to the section it is about, or in one column of boxes at the edge of the sheet when it concerns the whole sheet.
Notes live in boxes by kind¶
Rule. No free-standing text on a sheet apart from section headings: every note has a kind. The usual note is a KiCad text box of one of the kinds below, each with its colour, and a bold heading naming the kind. Long notes are split into several boxes, one per topic.
A short note can carry its kind in a prefix instead: the first word of its text, followed by a colon, names the kind (TODO:, Information: or Info:, Caution:, Debug:, Critical:, Layout:, Cost:, Ref:, case ignored). A prefix works on a free text without a box, such as Debug: J3 shorts the boot pin, and on a box of any colour, for a sheet that does not colour its notes. Two kinds also need no prefix: a cost line ($0.19 @25 · $0.12 @1k) is a Cost note by itself, and a text that starts with See and a list of note numbers (See N4, see N12, N14) is a Ref note by itself.
| Kind | Use for | Stroke colour | b125 original | Stroke |
|---|---|---|---|---|
| TODO | open work on the sheet | rgb(0, 131, 143) teal |
rgb(0, 194, 194) |
0.1524 mm dash |
| Information | design intent, how a value was found, how the circuit works | rgb(110, 110, 110) grey |
rgb(72, 72, 72) |
0.1524 mm dash |
| Caution | a trap for the next designer: do not change to X5R, keep this order | rgb(167, 118, 1) amber |
rgb(194, 194, 0) |
0.1524 mm dash |
| Debug | test points, jumpers, bring-up and simulation-only setup | rgb(232, 113, 10) orange |
rgb(221, 133, 0) |
0.1524 mm dash |
| Critical | a mistake here breaks or damages the board | rgb(210, 40, 70) crimson |
rgb(194, 0, 0) |
0.254 mm dash |
| Layout | placement and routing instructions for the layout | rgb(21, 101, 192) blue |
rgb(0, 0, 194) |
0.254 mm dash |
| Cost | the price of a part, a block or a sheet | none: a prefix or a cost line | none | none |
| Ref | a pointer to notes kept elsewhere: See N4, See N12, N14 |
rgb(230, 0, 160) magenta |
none | 0.1524 mm dot |
The colours in the table are only the fallback. A project sets its own colours by drawing them: a legend sheet with one text box per kind, each box's whole text the kind's name (Caution or Caution:) and its stroke the kind's colour. better_erc reads the legend from whichever sheet holds it and takes each kind's colour from its legend box, so the colours live in the schematic, where the reader sees them, and change with it. For example, a Legend page with seven boxes reading TODO, Information, Caution, Debug, Critical, Layout and Ref sets all seven colours; a kind without a legend box keeps the table's colour.
The setting drawing.note.colour.<kind> in the project file ([drawing.note.colour] caution = "rgb(194, 194, 0)") overrides both, for a project that cannot add a legend sheet. So each kind's colour comes from the setting, else the legend box, else the table. Every run that checks notes says in its notes where the colours came from, for example note colours (DRAW-32): TODO, Caution from the legend on /Legend/; Information, Debug, Critical, Layout, Ref the drawing guide's defaults; Cost none (prefix only).
The first six kinds and their dashed, unfilled boxes come from the front page of b125 (vb125_eth_fdcan_pro.kicad_sch). The colours are moved onto our KiCad theme (vhrd.json, vhrd_dark.json): TODO is the theme's current-probe teal, Caution its ERC-warning amber, Debug its voltage-probe orange, Critical its ERC-error crimson (lightened from rgb(169, 4, 62), which drops to 2.5:1 on the dark theme), Layout its bus blue, so a box reads as the same thing as the theme item it borrows from. Information is lightened from the b125 grey rgb(72, 72, 72), which drops to 2.1:1 on the dark theme; a box in that grey still reads as Information unless the project sets the colour or draws a legend. Ref is a dotted magenta box, set apart from the dashed notes because it holds no note of its own. Every colour keeps at least 3:1 contrast on white (PDF) and on the VHRD Dark background rgb(15, 15, 16); the Information grey has 5.1:1 and 3.8:1.
Each box is a group of two items:
- heading: free text, the kind's name (
Caution, optionallyCaution: back-feed), KiCad default font, 1.27 mm, bold, in the kind's colour, justified left top, inset 0.95 mm from the box's top-left corner; - body: a text box, KiCad default font, 1.27 mm, normal, theme text colour, justified left top, no fill, the kind's stroke, margins 0.95 mm with 3.2 mm at the top to leave room for the heading; width and height on the 1.27 mm grid.
No item carries a face: everything uses the default font, so one setting changes the whole sheet. In KiCad 10 that setting is appearance.default_font in the user's eeschema.json (Preferences > Schematic Editor > Display Options > Default font), not a project setting: our PCs set it to IBM Plex Sans, the brand font, and kicad-cli reads it too. A PC without it plots the stroke font, so boxes are sized for the wider stroke font; the b125 title font (Orbitron) stays on the front page logo. better_erc measures text in the same default font (drawing.font, else KiCad's).
Why. Loose text has no owner and no weight: a reviewer cannot tell a design reason from a forgotten TODO or a layout instruction that must not be missed. A box by kind says at a glance what the text is and how much it matters, and the layout engineer reads the blue boxes and nothing else. The colour only repeats what the heading says, so a black and white print loses nothing (colour).
Source. house (Roman, 31 Oct 2026; the b125 front page). Checks: DRAW-32 (free text, or a note of no kind by box colour or prefix).
Note boxes are lists and tables, not paragraphs¶
Rule. A note box has a short lead line, then numbered or bulleted items, one fact each, in short complete sentences of at most drawing.note.item_words words (default 15). Parameters and part lists go in a table. Avoid chains of colons, semicolons and brackets: split them into items. Section parameter boxes are a small name and value table, or two or three short lines.
Why. A stream of clauses is hard to read and harder to check; a list shows each fact and each gap.
Example.
bad: SLESD8D15C at the connector, R1213 680 R anti-surge, BAT54S: upper diode to a clamp bus
held at ~3.15 V by an ATL431 (self-powered by the fault, not tied to +3V3); R1215 100 R ...
good: Portwright rev B proposal for a 12 V claim.
1. The fault itself powers the clamp bus.
2. The clamp bus is not tied to +3V3.
Source. house (Roman, 31 Oct 2026, round 4 review). DRAW-47, DRAW-33
A note about a part points at it¶
A note box that is about a particular part or block draws a leader to it: a dotted line in leader purple rgb(142, 92, 205) (4.6:1 on white, 4.2:1 on VHRD Dark), 0.1524 mm, with an arrowhead at the target, bent in orthogonal or 45° segments around wires, parts, labels and text, never through them. The last segment into a small part (R, C, diode, TVS, 2 to 4 pins) is a 45° diagonal aimed at the centre of the body, and its tip stops drawing.leader.clear (default 0.635 mm) before the outline, so the head is never clipped by the part. A block pointed at this way gets its own rectangle (same purple, dotted, 0.1524 mm, no fill) around it. KiCad 10 has no arrowheads on lines: the head is a small filled triangle (a closed polyline, 1.27 mm long, 0.9 mm wide, filled with the stroke colour) grouped with the line and the box. Why: the reader sees which part a note is about without matching references by eye, and a diagonal into the body reads better than a straight line ending beside it (Roman, 31 Oct 2026: D513 good, D1212 clipped). DRAW-37, DRAW-38, DRAW-46
Tables, not lumps of text¶
Values that line up in rows and columns (pin options, a parameter sweep, a configuration matrix) go in a KiCad table (Place > Table, KiCad 8 and later), not in a text block padded with spaces. Why: a table stays aligned in every font and every PDF. DRAW-33
Grid, alignment and spacing¶
Everything that connects sits on the 1.27 mm grid¶
Symbols, wires, labels and sheet pins on 1.27 mm (50 mil); a finer grid only for text and graphics. Why: KiCad connects only coinciding points, and an item half a step off looks connected and is not. DRAW-3, WIRE-3
Neighbours line up exactly, or clearly not¶
Alignable things near each other share a column (x) or a row (y) exactly: label anchors, power and ground symbols, the vertical wires of ties, part edges and centre lines. "Near" is on the same side of the same part, or within drawing.align.window (default 20.32 mm) of each other. An offset that is not zero but under drawing.align.snap (default 5.08 mm, two major grid steps) is a near miss and gets fixed; a larger offset is deliberate and fine. Select them and use Align (KiCad 10). Why: a step off reads as careless and hides what belongs together, while a clear offset reads as a different group. Source: house (Roman, 31 Oct 2026: +3V3_LDO and a GND on the same side of the TMUX1511 in different columns, a label start off its tie column). DRAW-36, DRAW-10 (label columns)
Ladders: one row for ground, one for supplies, ports in columns¶
Within a section, all ground symbols sit on one row, all supply symbols (and the PWR_FLAGs beside them) on one row, input labels or ports in one column on the left and output labels or ports in one column on the right; a ground drop or a supply riser is as long as it needs to be to reach its row. Sections side by side may share the rows. Why: the eye reads the section as a ladder between two rails, and a symbol out of its row stands out as the odd one. Source: house (Roman, 31 Oct 2026, two sheets of a real board). DRAW-36 (per section: ground symbols, supplies, input ports, output ports)
Room around everything: clearance margins¶
Rule. Every item keeps a clear margin around it that nothing else enters: symbol bodies, power and ground symbols, fields and labels. Between sections the gap is bigger (sections).
Why. A sheet where every gap is the minimum reads as one block, and a field 0.3 mm from the next part's pin is read as belonging to it. Dense sheets (our own denser real boards) look tidy at the editor's zoom and become a puzzle at page width.
Settings. The margins are named drawing settings with defaults, used by every spacing check (DRAW-9, DRAW-34); a project sets its own in its better_erc project file:
| Setting | Default | Margin around |
|---|---|---|
drawing.clearance.part |
1.27 mm | a symbol's body and its pins |
drawing.clearance.power |
1.27 mm | a power or ground symbol and its name |
drawing.clearance.text |
0.635 mm | a field, a label, a pin name or number, a note box |
drawing.clearance.packed |
0.127 mm | a part's body, pins and fields against another part's, in tight spacing |
Two items are too close when their boxes, each grown by its own margin, overlap: two parts closer than 2.54 mm (one major grid), a field closer than 1.905 mm to another part, two labels closer than 0.635 mm. Two texts share one margin, the larger of theirs, and a power symbol counts as text, since its box is mostly its name. For example, two ground symbols side by side need 1.27 mm between their names, so a row of them at 5.08 mm pitch passes. A part's own fields and pin names against its own body are exempt (they sit next to it on purpose); a label against the wire it lies on is exempt, and so is a wire against the sheet box whose pin it ends on. drawing.clearance.spacing is tight by default: parts packed on purpose (a resistor pair at grid pitch, a column of test points) keep only the packed margin between their bodies, pins and fields; sparse holds them to the full margins.
bad: +3V3 ┬ good: ┬ +3V3
─────*──[R5 10k]── ───*─────┘
(name over R5: the power │ (stub long enough
symbol on a one-step stub ──[R5 10k]── that the name clears R5)
beside a series part)
Source. new (Roman, 31 Oct 2026: a dense real board was too crowded, make it configurable, do not overdo the default); standard: AoE (space around symbols). Checks: DRAW-34, DRAW-9.
Pins never join pins¶
Two pins meet through at least the pin lead (1.27 mm, 50 mil) of wire, never pin end on pin end. Why: a pin-on-pin joint is invisible, has nowhere to add a branch, and opens silently when one part is moved. DRAW-29
Straight out of a pin, straight into a power symbol¶
A wire leaves a pin along the pin's own axis for at least the pin lead (1.27 mm, 50 mil) before its first bend, and enters a pin or a power or ground symbol the same way: no bend right at a pin end. Why: the direction of the pin and of the symbol stays readable, and a corner at a pin end is not mistaken for a junction. Source: house (Roman, 31 Oct 2026, the VDD pin of a real board's TMUX1511 bending straight up into +3V3_LDO). DRAW-41 (drawing.pin_lead, default 1.27 mm)
A test point is the exception: its tip may touch a wire from any side, at the wire's end or in its middle. A test point marks a place on the net where a probe lands, so it leads nowhere and has no direction to keep readable. For example, a probe-shaped test point whose tip rests on a horizontal signal wire is drawn right. Other one-pin symbols (a mounting hole, an antenna feed) have a lead like any part and follow the rule.
Signal flow¶
Signals run left to right¶
Inputs on the left, outputs on the right, feedback above or below the forward path. Why: the sheet reads like a sentence and a missing part in the path stands out. DRAW-12
Power flows left to right, high to low voltage¶
Input on the left, the rails it makes to the right in falling voltage. Why: the sheet reads as the power tree.
Connectors at the sheet edge, with their protection beside them¶
Connector at the edge its signals come from, its TVS, fuse or series resistor right next to it, between it and the rest. Why: the reviewer sees at once that every line passes its protection first. DRAW-14
Library orientation is the default¶
Draw an IC or a multi-pin part the way the library drew it. Rotate two-pin parts freely; mirror symmetric parts and transistors freely. Mirroring a multi-pin part, or placing it upside down, is still fine when it makes the signal flow read better, such as a level shifter whose line side faces the connector it serves. Why: library symbols put inputs left and outputs right, so the default keeps the flow readable; a hint only, never a warning, since the drawer can see the flow better than the tool. DRAW-12
Decoupling and bulk capacitors stand vertical¶
A capacitor between a supply and ground (decoupling, bulk) is drawn vertical: rail end up, ground end down. Why: the capacitor then sits on the vertical voltage axis, and a row of them reads at a glance as the rail's decoupling. Other parts tied to a supply or ground may lie either way. A pull-up runs from its rail to the signal it holds, and a series ferrite or a shunt resistor sits in the power path, so lying horizontal reads right for them. DRAW-35
Power and ground¶
Ground symbols point down, supply symbols point up¶
Ground below its pin pointing down, positive supplies above pointing up, negative supplies down. Why: the vertical axis reads as voltage. DRAW-1, DRAW-2
Power net names: +VOLTAGE_SOURCE¶
Rule. A power net is named +<voltage>_<group or source>, the voltage with V as decimal point: +3V3_LDO, +1V8_REF, +5V_USB, +12V_IN, +3V3_MCU; negative rails -5V_<source>. The suffix says where the rail comes from (LDO, BUCK, USB, IN, REF) or which group it feeds (MCU, ANA, ETH). A plain +3V3 is fine on a board with one 3.3 V rail. An adjustable rail has no fixed voltage to name, so it is named +<name>_ADJ instead, like +VIO_ADJ. Grounds are GND, AGND, PGND, GND_<group>.
Why. The name is all a reader sees at a power symbol. Two 3.3 V rails both called +3V3_x show they are different nets with the same voltage, and the suffix says which regulator to look at; a name without the voltage (VCC, V_MCU) sends the reader to the power tree for every pin. The + and the V as decimal point are what our tools and KiCad's simulator parse as a voltage (NAME-7, NAME-11).
Example.
Source. house (Roman, 31 Oct 2026). Check: NAME-13; NAME-3 (no voltage in the name), NAME-11 (negative rail without its sign).
One power symbol per rail per pin group¶
Rule. Several pins of one part on the same rail (the four GND pins of a connector, the VDD pins of an IC) are wired together with short stubs and reach that rail through one power or ground symbol, not one symbol per pin. The unit is a pin group: pins of that rail next to each other on one side of the body. Two groups on different sides get a symbol each when one shared symbol would need a detour that costs more than the second symbol (routing is a weighed compromise). Between parts, neither drawing is wrong: several parts on one rail (a divider, a reference and its capacitor; an LDO's diode, capacitor and load) may share one rail wire with one symbol, or each drop straight to a symbol of its own on the section's power row; the routing cost picks, and the cheaper wins (usually the straight drops). A decoupling capacitor keeps its own symbol.
Why. Twenty ground symbols mashed under one IC are noise: the reader counts symbols instead of seeing that "all ground pins go to ground". One wire collecting the pins says it once and leaves room for the pins that matter.
Example.
Source. house (Roman, 31 Oct 2026, on a real board's TMUX1511 and its four grounded selects; third review: a rail wire or a symbol per part, let the cost decide); new for the exception of decoupling. Checks: DRAW-30, DRAW-40.
Power symbols, not long wires, to reach a rail¶
Reach a rail through a power symbol at the part, not a wire across the sheet. Why: a rail wired across a sheet crosses every signal.
Power symbols from vhrd_power, rails coloured by net class¶
Rule. Power and ground symbols come from our kicad-library repo's vhrd_power library: GND for ground and the board rails, PWR_LOCAL (a KiCad 10 local power symbol, its value is the net name) for a rail that must stay on its sheet: a simulation bench, a sheet that stands for a board of its own. The project's net classes colour the rails, not the symbols one by one:
| Net class | Patterns | Wire colour | Symbol colour |
|---|---|---|---|
| Ground | GND |
rgb(0, 115, 30) dark green |
GND in a lighter green rgb(60, 170, 24) |
| Power | +*, */+* (a local rail is /<sheet>/+3V3_LDO) |
rgb(175, 50, 10) burnt orange |
PWR_LOCAL and the other vhrd_power supplies in orange rgb(232, 113, 10) |
The symbol orange is the Debug box orange and the theme's voltage-probe colour, the one the vhrd_power supply symbols already had. A symbol and its wires differ by more than drawing.colour.pair_min (neighbours in different colours), and all four keep about 3:1 on both the white and the VHRD Dark background, since net class and library colours do not change with the theme.
Why. A reader finds the rails of a sheet at a glance, and a power net named after the rule above (power net names) is coloured without anyone setting a colour by hand. The colour only repeats what the + in the name says (colour). A local power symbol keeps the per-sheet rails of a bench apart without hierarchical labels.
Source. house (Roman, 31 Oct 2026: a real board project's net classes, the vhrd_power symbols).
Decoupling next to the pin it serves¶
Each decoupling capacitor beside its power pin, in the order of the pins. Why: the layout is placed from the schematic, and caps drawn in a pile end up in a pile. DRAW-15, LAY-17
Wires and junctions¶
Wires are horizontal or vertical¶
90° line mode only. Why: diagonals cross more and miss the grid at joints. DRAW-5
No 4-way junctions¶
Stagger four wires into two T junctions, each with a dot; turn on KiCad's four_way_junction ERC check. Why: a 4-way joint and a crossing differ only by a dot that a print can lose. WIRE-15, DRAW-4
Crossings: a plain cross never connects¶
Avoid crossings; on busy sheets set a hop-over size (KiCad 10, Schematic Setup > Formatting). Why: each crossing is a place the eye jumps to the wrong wire.
Wires never run through a symbol, a label or text¶
Why: a wire over a body looks like a pin connection, over text it makes both unreadable. This holds for the wire of a one-pin symbol's own net too: a test point pad or a mounting hole drawn as a circle sits at the end of its pin, and its wire ends at the pin's tip instead of running through the circle. DRAW-7
Routing is a weighed compromise¶
Rule. Where a tie can be drawn more than one way (pins to a power symbol, a few pins tied together), the cheaper drawing wins, by a cost the guide fixes and better_erc scores:
| Term | Setting | Default | Counts |
|---|---|---|---|
| length | drawing.route.w_len |
1 | per major grid step (2.54 mm) of wire |
| bend | drawing.route.w_bend |
2 | per bend |
| crossing | drawing.route.w_cross |
4 | per crossing with another net: a crossing is worth about four grid steps of detour |
| crossing near a pin or junction | drawing.route.w_cross_near |
8 | instead of w_cross when the crossing is within one grid step of a pin end or a junction, where it reads as a connection |
| extra symbol | drawing.route.w_symbol |
6 | per power or ground symbol beyond the first of that rail on the part |
| detour | drawing.route.w_detour |
4 | per unit of (drawn length / Manhattan length − 1) of the tie |
Power and ground ties weigh more than signals: their bends and detours count drawing.route.k_power and drawing.route.k_ground times (default 2 each, drawing.route.k_signal 1), and any bent power or ground tie is looked at, so a supply goes straight up from its pin (after the pin lead) and a ground straight down. A redraw must save at least drawing.route.min_saving (default 2) to be reported; the drop to the section's power or ground row (ladders) is not a detour.
The Manhattan length of a tie is the rectilinear distance it must cover at least (the half-perimeter of the box around its pins and symbol). So a straight drop to ground that crosses one stub costs less than a loop around the part, and a second ground symbol costs less than a long way round.
Why. "Avoid crossings", "one symbol per part" and "short wires" pull against each other; stated as costs, the trade is made the same way on every sheet and by a tool, instead of by whichever rule the drawer remembered.
Example. Grounded switch pins D2..D4 on the right of a part whose GND pin 7 is at the bottom left:
bad: around the part to the GND pin good: straight down, across VDD, a second symbol
┌──────┐ ┌──────┐
│ D2 ├──┐ │ D2 ├──┐
│ D3 ├──┤ │ D3 ├──┤
│ D4 ├──┤ │ D4 ├──┤
│ VDD ├──│──── +3V3 │ VDD ├──┼──── +3V3
│ GND │ │ │ GND │ │
└──┬───┘ │ └──┬───┘ ┴ GND
├──────┘ ┴ GND
┴ GND
cost: 12 grid + 2 bends + detour 3 = 19 cost: 4 grid + 1 bend + 1 crossing + 1 symbol = 16
Source. house (Roman, 31 Oct 2026, the ties of a real board's TMUX1511; second review: the BAT54S rail ran sideways, power and ground weigh more); the weights are new. Check: DRAW-40.
No stray wire pieces¶
No zero-length or overlapping wires. Why: they make junctions nobody drew. DRAW-6
Labels and hierarchy¶
Wire within a section, label between sections¶
Wires inside a section, labels for nets that would cross the sheet. Why: short wires show topology, labels keep long nets from crossing everything.
The narrowest scope that works¶
Local labels on one sheet, hierarchical labels and sheet pins between sheets, global labels only for nets that are truly everywhere. Why: the scope says where to look for the other end. WIRE-6, WIRE-12, WIRE-4
Labels lie on their wire, justified by side¶
Rule. A label sits on a horizontal wire stub, its text lying along that stub, never off its end in the air. On the left side of a block the label is at the left end of its stub and left-justified, the text running right along the wire toward the block; on the right side it is at the right end and right-justified, the text running left toward the block. The stub is at least as long as the text plus one grid step, so the text never reaches the pin. A label wanted on a pin or on a joint gets its own stub, joined with a junction dot.
Why. Text over its wire says which wire it names; text sticking out past the wire end floats next to nothing and can be read as naming the wire below. Left side left-justified and right side right-justified line the label ends up with the sheet's outer edge of each block, so the columns of labels read like a pin list.
KiCad 10. The side a local label's text runs to comes from its justification, not from its angle: a label at 0° with justify right runs left. Set the justification (label properties) rather than rotating the label, and check it after copying labels from an older sheet. In the file: left side (at x y 0) with (justify left bottom), right side (at x y 180) with (justify right bottom).
bad: SEL ──────┤SEL1 good: SEL──────────┤SEL1 V3V3───*
(text left of the wire end, (text along the stub) ├VDD (pin)
hanging in the air)
Source. house (Roman, 31 Oct 2026); standard: Hack Club (labels sit on a wire). Checks: DRAW-28, DRAW-11 (vertical labels), WIRE-3 (dangling labels).
Sheet pins: inputs left, outputs right¶
Inputs on the left edge of the sheet symbol, outputs on the right, power at the top. Why: the parent sheet reads as signal flow. DRAW-13
Buses for groups of signals that go to many places¶
A group of related nets that each reach three or more places (an IO expander's port, an I2C or SPI bus shared by several parts, a parallel data bus, DDR) is drawn as a KiCad bus: a bus wire with entries, a vector name D[0..7] or a group name with an alias {SDA SCL}, every entry labelled. Signals that do not travel together get no bus. Why: one bus line says "these go together to all of these places" where a dozen scattered labels make the reader collect the group by name, and a bus of unrelated signals hides them. Source: house (Roman, 31 Oct 2026); KiCad bus aliases. DRAW-39 (a hint), WIRE-16
Text¶
Reference and value horizontal, next to the part¶
Shown on every part, horizontal, beside or above the body; O (Autoplace Fields) after rotating. A field's angle is relative to its symbol: horizontal text on a part rotated by 90° has a field angle of 90°. Why: vertical text is read with a tilted head and collides with wires first. DRAW-8, DRAW-22
Text sizes¶
| Text | Size | Weight |
|---|---|---|
| fields, labels, pin names, note and parameter box bodies, table cells | 1.27 mm | normal |
| note box headings | 1.27 mm | bold |
| section headings | 2.54 mm | bold |
| group headings inside a section (a block of parameters, a sub-circuit) | 1.905 mm | bold |
Nothing below 1.27 mm. Why: 1.27 mm is the smallest that survives an A3 printed on A4. DRAW-24
Sentences start with a capital letter¶
Prose in text boxes, notes, headings and table cells starts each sentence with a capital letter; a line that starts with a net or part name, a unit, a value or code (.param, mA, i(V1290), nX) stays as it is. Why: a note reads as a sentence, not as a fragment cut from somewhere. Source: house (Roman, 31 Oct 2026). DRAW-43
No text over text, a body or a wire¶
Why: overlapping text is unreadable, the most common reason a sheet looks messy. DRAW-9
Parts¶
Unused pins get a no-connect flag¶
Only after the datasheet allows it. Why: the flag records that the pin is open on purpose. WIRE-8
DNP is an attribute¶
Set the DNP attribute and keep the real value. Why: a value of "DNP" is still bought and placed. DRAW-23, BOM-13
Multi-unit parts: units near their circuit, power unit placed¶
Why: an unplaced unit leaves inputs floating and hides the rail. LIB-14, LIB-13
Simulation-only parts are drawn apart and marked¶
Ammeters (0 V sources), fault sources, switches and behavioural models that exist only for the simulator use their own symbols (an ammeter is vhrd_sim:AMMETER, a teal circle with an arrow from + to -, the direction of positive current, not a battery), sit together at the edge of their section or in a Debug box's area, and are excluded from the BOM (in_bom no). They stay on the board (on_board yes): the XML netlist drops off-board parts, and a simulation driver that maps references through it (spicejob) then loses them. Why: a reader must see at a glance which parts are the circuit and which are the test bench around it.
Fault cases in one table on the first page¶
A project simulated case by case (spicejob) lists every case on its first sheet in one KiCad table: one row per case, named exactly as in sim/*.toml and the simulator output (p5, n12, bfin, ...), with the outside state (fault voltage, source and cable, plug-in time), the inside state (powered or not, pin hi-Z or driving, target present, other controls), what the case tests and which sheets run it (expected fails marked). Generate it (spicejob cases DIR --format kicad-table), do not type it. Why: sheets and simulation output then map one to one, and a reviewer sees what was tried before reading any result. Source: house (Roman, 31 Oct 2026, a real board).
Simulation directives grouped, each explained beside it¶
SPICE directives (.param, .tran, .options) are text boxes with exclude from simulation off, one box per group of meaning (fault source, target, rails, controls, timing) under a group heading, with a second box flush to its right that explains each line on the same line. KiCad reads directives from text and text boxes, not from table cells, so the explanation is a box beside it rather than a table column. Why: forty .param lines in one text block hide which parameters belong together, and an explanation in a separate block is matched line by line by eye. Source: house (Roman, 31 Oct 2026, a real board's index sheet).
Colour, print and export¶
Colour adds, never carries meaning alone¶
Keep the theme's colours for wires, labels and text; hand-set colour only where a name or a heading already says the same (the note box kinds). Why: black and white prints, other themes and colour-blind readers lose colour. DRAW-27
Neighbours in different colours¶
Every pair of items that touch is told apart at a glance: a wire and the pin it ends on, a wire and its power or ground symbol, a wire and its label. The two colours differ by at least drawing.colour.pair_min (CIEDE2000, default 20) on both the light and the dark theme, and each keeps 3:1 on its background where the colour is the same for both themes (net classes and library symbols are). Our set:
| Item | Where it is set | Light (vhrd.json) |
Dark (vhrd_dark.json) |
|---|---|---|---|
| wire | theme wire |
rgb(90, 90, 90) (ΔE 20.9 to the label text) |
rgb(154, 154, 154) (ΔE 20.9) |
| pin | theme pin |
rgb(150, 108, 0) gold (ΔE 29.0 to the wire, 32.9 to the outline) |
rgb(232, 196, 82) gold (ΔE 26.9, 43.7) |
| ground wire | net class Ground | rgb(0, 115, 30) |
same |
| ground symbol | vhrd_power:GND |
rgb(60, 170, 24) (ΔE 20.5 to its wire) |
same |
| power wire | net class Power | rgb(175, 50, 10) |
same |
| power symbol | vhrd_power supplies, PWR_LOCAL, PWR_FLAG |
rgb(232, 113, 10) (ΔE 22.9 to its wire) |
same |
The pin is gold, clear of the wire, the symbol outline and the Critical box red; the symbol of a rail is the lighter member of its family and its wires the darker one, so the long runs stay calm and the symbols stand out. Why: where a pin and its wire are the same grey, the reader cannot see where the part ends, and a green ground symbol on a green wire melts into it. Source: house (Roman, 31 Oct 2026). DRAW-42
Check the PDF before a review¶
Plot to PDF with the drawing sheet and read it at 100 % and printed in black and white. Why: the PDF is what reviewers and assemblers see.
KiCad settings and shortcuts¶
Command names and default hotkeys of KiCad 10.0 (from its source); the same in 9.0 except where marked.
| Want | KiCad 10 |
|---|---|
| Snap a group to the grid | select, right-click > Align Items to Grid (eeschema.AlignToGrid, no default hotkey: assign one in Preferences > Hotkeys) |
| Line up labels or parts | select several, right-click > Align > Align to Left / Right / Top / Bottom / Horizontal Center / Vertical Center (new in 10, no hotkeys, no distribute) |
| Fields back in place, horizontal | Autoplace Fields O; Preferences > Editing Options: "Automatically place symbol fields", "Always align autoplaced fields to the 50 mil grid" (both on by default) |
| Label side | label properties > justification (left side: left, right side: right); the angle no longer sets the side |
| Grid | 50 mil (1.27 mm) default; N / Shift+N next / previous grid, Alt+1 / Alt+2 fast grids; grid overrides (Ctrl+Shift+G): connected items and wires 50 mil, text 10 mil |
| Rotate, mirror | R (counter-clockwise), Shift+R (clockwise), X mirror left-right, Y mirror top-bottom |
| Move or drag | M move (breaks connections), G drag (keeps them) |
| Wires straight | line mode 90° (Shift+Space cycles free / 90° / 45°) |
| Labels in a column | L label, then Insert repeats the last item one step down with its number incremented (SDA0, SDA1, ...) |
| No-connect, junction | Q, J |
| Note box, table | Place > Text Box; Place > Table (KiCad 8 and later) |
| Group a heading with its box | select both, right-click > Grouping > Group (KiCad 10 schematic groups) |
| Edit fields | E properties, U reference, V value, F footprint |
| Follow a net | ` highlight net |
| DNP | right-click > Attributes > Do not Populate; variants in Schematic Setup (10) |
| Formatting | Schematic Setup > Formatting: text size 50 mil, junction dot size, label offsets, hop-over size (10, default None) |
| Title block | File > Page Settings (or double-click the frame), "Export to other sheets"; text variables ${REVISION}, ${#}, ${##}, ${COMMENT1} |
| 4-way junction check | Schematic Setup > Electrical Rules > Violation Severity: "Four connection points are joined together" (four_way_junction), off by default: set it to warning |
| Print, export | File > Plot: PDF or SVG, colour or black and white, with or without the drawing sheet |
What other tools automate¶
- Altium Designer: Align Left / Right / Top / Bottom (
Shift+Ctrl+L,R,T,B), equal spacing (Shift+Ctrl+H), Align To Grid (Shift+Ctrl+D), and an "Off-Grid Object" compile check. altium.com shortcuts, Off-Grid Object - OrCAD X Capture: an Align toolbar with Distribute Horizontally / Vertically. cadence.com
- KiCad: ERC catches off-grid ends, dangling labels, labels on several wires and 4-way junctions (when enabled); nothing checks orientation, spacing, fill or text overlaps.
- Third-party KiCad tools (KiBot, kicad-happy, kicad-tools, kicad-skip) run ERC or electrical reviews, or edit schematics from Python; none checks drawing style. That is what the
DRAWchecks are for.
House style measured¶
What our own sheets do today, measured on 30 Oct 2026 over a private set of 157 production sheets (133 of them with parts; KiCad 7 to 10 files) by reading the files themselves (positions, angles, fields, title blocks), not the netlist. Numbers are over the sheets with parts unless the line says otherwise. The rules Roman set on 31 Oct 2026 (power net names, label justification, one symbol per rail per part, sections, note boxes, tables, clearance, small parts vertical) are not measured yet.
| Habit | Measured | Verdict |
|---|---|---|
| Ground symbols down | 1837/1845 symbols, all down on 113/121 sheets | house style, keep |
| Supply symbols up | 535/535 | house style, keep |
| On the 1.27 mm grid | 121/133 sheets clean; 8 symbols, 66 wire ends, 32 labels off | house style; fix the rest |
| Diagonal or zero-length wires | 0 | house style |
| 4-way junctions | 17 on 16 sheets | rare; remove |
| Stacked labels aligned | 2289/3124 (73 %) | mostly; one command fixes the rest |
| Vertical labels | 200/3642 (5 %) | rare |
| Label scopes | 2339 local, 822 hierarchical, 481 global | hierarchy is the habit |
| Wires and labels per part | 4.3 wire segments, 1.0 label | balanced |
| Vertical reference / value | 298/3695 and 285/3268 (8 %) | mostly horizontal; O after rotating |
| Hidden references | 2 | house style |
| Text size | 10595 of 10605 texts at 1.27 mm | house style |
| Paper | A3 99, A4 54, A2 3, A0 1 of 157 | A3 is the house size |
| Fill of the usable area | median 46 %, 39 sheets under 30 % | room to use a smaller paper or centre |
| Centred within 10 % | 69/133 | half; new rule |
| Title, revision, date | 127, 108, 113 of 157 | mostly; revision missing on a third |
| Notes on the sheet | 102/133 any, 77/133 a calculation or reason | house style |
| Connectors at the edge | 158/417 in the outer fifth of the drawing | not yet a habit; new rule |
| Protection near the connector | 19/28 recognised TVS/ESD parts within 50 mm | mostly |
| DNP | 109 by attribute, 26 by text only | attribute is the habit; fix the text ones |
| Hand-set colours | 75/133 sheets | common; new rule says B&W must still read |
| Density | median 1.9 parts per dm², max 9.3 | fine |
Measuring this again is planned as a berc command, TOOL-7. The DRAW checks will report the same habits per sheet once NET-26 reads the drawing geometry.
Sources¶
Cited by the rules above that are not obvious; the obvious ones are common to all of them.
- KiCad · KiCad, Schematic Editor manual, 10.0: grid ("Snapping"), aligning, formatting, hop-overs, text variables, plotting. docs.kicad.org/10.0/en/eeschema/eeschema.html
- KiCad source · KiCad 10.0 source,
eeschema/tools/sch_actions.cpp(command names and default hotkeys),eeschema/tools/sch_align_tool.cpp,common/settings/app_settings.cpp(grids),eeschema/default_values.h(formatting defaults),eeschema/erc/erc_settings.cpp(ERC defaults). gitlab.com/kicad/code/kicad - KiCad 10 release · KiCad 10.0.0 Released (hop-overs, variants, local power symbols, groups). kicad.org/blog/2026/03/Version-10.0.0-Released
- KLC · KiCad Library Conventions, symbol rules S3 (general), S4 (pins), S6 (fields), S7 (power symbols). klc.kicad.org, source gitlab.com/kicad/libraries/klc
- IEC 61082-1 · Preparation of documents used in electrotechnology, Part 1: Rules, ed. 3 (2014): flow of energy and signal (7.1.1), connecting lines, joining and crossing (7.1.3), spacing of lines, reference designations at the symbol (7.1.6), title block (annex B). Paywalled; the section list is from the publisher's preview. webstore.iec.ch/publication/10551
- IEEE 315 · IEEE 315-1975 / ANSI Y32.2-1975, Graphic Symbols for Electrical and Electronics Diagrams; IEC 60617 is the international symbol set. standards.ieee.org/ieee/315/6396
- Wikipedia · Circuit diagram: left to right and top to bottom, positive supplies at the top, grounds and negative supplies at the bottom, 4-way connections staggered into two T junctions. en.wikipedia.org/wiki/Circuit_diagram
- AoE · Horowitz and Hill, The Art of Electronics, rules for good schematics (as kept by the xcircuit project). xcircuit.sourceforge.net/goodschem/goodschem.html
- EMA · EMA Design Automation, Schematic Guidelines Checklist (2021). ema-eda.com (PDF)
- Altium · Altium, Easy Schematics Creation for Elegance and Readability. resources.altium.com
- Hack Club · Hack Club Hardware Codex, Schematic practices. hwdocs.hackclub.dev
- KiCad forum · Best practices: pin-on-pin connection, junction dots. forum.kicad.info/t/13882