Skip to content

WIRE checks

The WIRE checks of the check catalogue. Each check has a page of its own: what it catches, why it matters, an example, how better_erc finds it, the usual fix and where to read more, with the test schematics that show it firing.

Most of these checks are about how a schematic is drawn rather than what it does: labels, flags, sheet pins and buses. A netlist has already resolved all of that into nets, so several checks here read the schematic itself (.kicad_sch, through the s-expression reader berc textconv uses, TOOL-3) instead of the netlist.

References used throughout:

Checks

Check Severity Status
WIRE-1 Net with a single pin (a label with no partner, a typo in one of two labels) warning runs
WIRE-2 Net names that differ only in case, separator or suffix (RESET_N and RESET_n, 3V3 and +3V3): almost always one net meant error runs
WIRE-3 Label not attached to a wire or pin (dangling, offset by a grid step) warning planned
WIRE-4 Hierarchical sheet pin without a matching label inside the sheet, or unconnected on the parent error planned
WIRE-5 Power symbol and a signal label with the same name: the signal is silently on the rail error planned
WIRE-6 Global label used on one sheet only, where a local label was meant (or the other end is misspelled) warning planned
WIRE-7 No-connect flag on a pin that also has a wire error planned
WIRE-8 Unconnected pin without a no-connect flag: not decided, or forgotten warning planned
WIRE-9 No-connect flag on a pin the datasheet says must be tied (an unused input, a mode pin, an exposed pad) error planned
WIRE-10 Hidden power pins on a symbol connected implicitly by name: the connection is not visible on the sheet warning planned
WIRE-11 Unnamed (auto-named) net with many pins or crossing sheets: give it a name suggestion runs
WIRE-12 Same label text in different scopes (a local and a global label, a sheet pin and a global label): joined in one tool, separate in another, and the designer assumes one of the two error planned
WIRE-13 Output pin whose net reaches no input (an output into nothing but passives or a test point) warning runs
WIRE-14 Ground-named pin (GND, VSS, AGND, PGND) on a net that is not a ground error runs
WIRE-15 Four-way wire junction, or a label placed over several wires: the connection is ambiguous to a reader suggestion planned
WIRE-16 Bus mismatch: a member net not in the bus it joins, bus widths that differ, indices out of range error planned
WIRE-17 ERC or DRC rules silenced in the project file: list them in the report, they hide findings suggestion planned