erc_levels holds what each logic family, bus and differential standard defines for its levels: the supply range, the input thresholds, the output levels with the currents they are tested at, input currents, hysteresis, differential swing and common mode, termination. Level checks (LVL-2, LVL-3, LVL-10; DIAG-7) and simulations read their limits from it instead of numbers typed from memory.

The loader hands out values as exact_units types: Volts, Amperes, Ohms and Farads are Fixed<Volt, One, f64> and so on, test currents are MilliAmperes, temperatures are DegC (a point on the Celsius scale), and a unit's dimension is an exact_units::Dim. Level::limits gives a row's min, typ and max as a Quantity of the right dimension, Level::volts and Level::amperes as voltages or currents.

The data is one TOML file, erc_levels/data/signal_levels.toml, embedded in the crate (Database::builtin()).

What it covers

  • Logic families: 74LS, 74ALS, 74F, 74HC, 74HCT, 74AC, 74ACT, 74LV-A, 74LVC, 74LVC1G, 74ALVC, 74AUP, 74AVC, 74AXC and 74AXP at each supply their datasheets specify, and CD4000B at 5, 10 and 15 V.
  • JEDEC interface levels: LVTTL and LVCMOS at 3.3, 2.5, 1.8, 1.5, 1.2 and 1.0 V (normal and wide range, with the Schmitt-trigger tables), SSTL_3, SSTL_2, SSTL_18, SSTL_15, SSTL_135, SSTL_125, DDR4 command/address, POD12, HSTL at 1.8, 1.5 and 1.2 V, HSUL_12, GTL and GTL+.
  • Buses: I²C (Standard-mode, Fast-mode, Fast-mode Plus, Hs-mode, Ultra Fast-mode), SMBus 3.3 (low and high power), I3C (through a target's datasheet), 1-Wire, RS-232, RS-422, RS-485, CAN (classic, FD and SIC), LIN, SD (3.3 V and UHS-I 1.8 V), MIPI D-PHY, and SPI, UART, JTAG and SWD as interfaces without levels of their own.
  • Differential logic and clocks: LVDS, M-LVDS (Type 1 and 2), sub-LVDS, SLVS-400, LVPECL, PECL, ECL 10K, 10KH, 100K and 100EP, CML, HCSL and LP-HCSL.
  • Serial links: USB 2.0 (low, full and high speed), USB 3.2 SuperSpeed, USB Type-C CC, USB PD BMC, Ethernet MII, 10BASE-T, 100BASE-TX, 1000BASE-T, 100BASE-T1 and 10BASE-T1S, HDMI TMDS, DisplayPort, PCIe Gen1 to Gen3.

cargo run -p erc_levels --example validate prints how many families, documents and levels there are, and how many of the levels are verified.

Where the numbers come from

Every family names a source document, and every value says whether it was read there:

  • [docs.ID] describes a document: title, publisher, number, revision, date, the URL it was fetched from, and its file in the technical library (library, relative to the library root). The document is the standard itself where it is free (NXP UM10204 for I²C, the USB specifications); where the standard is behind a paywall or a login it is the best free substitute, and says so: the standard's harmonised twin (JEITA for JEDEC), a vendor handbook or application note, or a transceiver datasheet (for ISO 11898-2, TIA-485, TIA-232). kind and substitute_for record which.
  • source = { doc, loc } on a family is the default document and location (table and page) of its values; a value can name another document (doc) or location (loc).
  • verified = true means the number was read from that document at that location. A number from anywhere else (memory, a secondary source, a reasonable assumption such as a supply range the standard leaves open) stays verified = false and its note says why.

A datasheet substitute gives one part's guaranteed numbers, which meet the standard but may be tighter than it; the family's notes say so where it matters.

Format

[family.i2c-fm]
name = "I²C Fast-mode (400 kbit/s)"
group = "I2C"                       # the family the variants belong to
kind = "open-drain"                 # single-ended | open-drain | differential | bus | no-levels
standard = "UM10204 Rev. 7.0, Fast-mode"
source = { doc = "UM10204", loc = "Table 10, p. 43" }
supply = [
  { name = "VDD", min = 1.65, max = 5.5, verified = false, note = "UM10204 sets no VDD range" },
]
level = [
  { param = "VIL", min = -0.5, max = "0.3*VDD", unit = "V", verified = true },
  { param = "VOL", max = 0.4, unit = "V", iout_ma = 3.0, cond = "VDD > 2 V", verified = true },
]
  • One table per standard and supply variant: 74lvc-3v3 and 74lvc-1v8 are separate families of group 74LVC.
  • supply lists the supplies and references in order; the first is the main one. A later one may refer to an earlier one (VREF = "0.5*VDDQ", a termination voltage "VCC-2").
  • A limit is a number in the row's unit (V, mV, Vppd, mVppd, A, mA, uA, nA, ohm, kohm, pF, nF), or a linear expression of a supply in volts: "0.7*VDD", "VDD-0.4", "VCC-1.025", "VREF+0.1".
  • iout_ma is the output test current with JEDEC's sign, positive into the pin: an IOH test is negative. vsupply is the supply a row is specified at (74HC's thresholds at 2.0, 4.5 and 6.0 V). temp_c narrows a row to a temperature range, t_c to the one temperature it is given at (ECL's 0, 25 and 85 °C columns), state to a bus state or mode (dominant, recessive, high-speed).
  • loc gives pages as the PDF's own page numbers (the file's first page is p. 1), which can differ from the number printed on the page.
  • Parameter names: single-ended VIH VIL VT+ VT- VHYS VOH VOL IIH IIL II IOZ IOH IOL IOS CI, differential VOD dVOD VOS dVOS VTH VTL VID VIC VCM RIN RTERM. Any other name needs a desc; its first letter gives its dimension.
  • kind = "no-levels" is for interfaces with no electrical standard of their own (SPI, UART at logic level, SWD and JTAG): the notes say which levels they run at in practice.

Checks on the data

Database::validate() (run by the crate's tests) reports:

  • documents that are unknown or unused, and verified values whose document is not in the library or that have no location;
  • min <= typ <= max, evaluated at the low, typical and high supply corners;
  • VIL below VIH and VOL below VOH for rows of the same supply, state and temperature, and VT- below VT+;
  • units that don't fit the parameter, rows of one parameter in different units, expressions in anything but V, expressions of a supply the family doesn't have;
  • families without levels (unless no-levels, which needs notes), unknown see references.

A test also checks that every document's file is in the library when the library is on the machine (BERC_LIBRARY_DIR, else ~/sync); without it the test says so and skips.

Adding a family

  1. Get the document (the standard, else the best free substitute), put it in the library, and add its [docs.ID] block with the printed number, revision and date.
  2. Add the family table, reading each number from the document; give the table and page in loc.
  3. Check the file: cargo run -p erc_levels --example validate (the embedded file), or with extra files to check a fragment before merging it: cargo run -p erc_levels --example validate -- fragment.toml.