Skip to content

DEC-6 Bulk capacitance on a rail below what its regulator or load needs

Severity Status Implementation
warning planned mid, depends on RPT-1, NET-5, CFG-2

Looks at. Capacitance per rail, derating, regulator data.

What it catches. A rail whose total capacitance, derated for DC bias at the rail voltage, is below the minimum the regulator needs at its output or the load needs for its current steps.

Why it matters. Regulators are stable and meet their transient spec only with a minimum output capacitance; loads that switch large currents (radios, motors, SoCs leaving sleep) need charge nearby so the rail stays above their brown-out level until the regulator responds. Ceramics lose much of their capacitance under DC bias, so "22 µF" on the schematic can be 8 µF on the board.

Example. A Wi-Fi module on a 3.3 V buck with 2 × 10 µF 6.3 V 0603 X5R: well under 10 µF effective at 3.3 V. Its transmit bursts draw several hundred mA within microseconds, faster than the buck's loop answers, and the rail sags below the module's brown-out threshold at every burst.

How to check. Sum capacitance per rail (RPT-1) with a DC-bias derating per package and dielectric, compare with the regulator's minimum (library) and a load requirement from the project (CFG-2).

Fix. More or larger-case capacitors, a polymer or tantalum bulk capacitor; check the regulator's maximum too (RAIL-21).

References. AN4488 §8.3 (bulk 4.7-10 µF per rail); MT-101 "Types of decoupling capacitors"; AoE3 chapter 9.