Skip to content

BAT checks

The BAT checks of the check catalogue. Each check has a page of its own: what it catches, why it matters, an example, how better_erc finds it, the usual fix and where to read more, with the test schematics that show it firing.

References used throughout:

  • BQ2407x · TI, BQ2407x Standalone 1-Cell 1.5-A Linear Battery Chargers with Power Path datasheet, SLUS810N (2021): power path, TS input. ti.com/lit/ds/symlink/bq24075
  • BQ297xx · TI, BQ297xx Cost-Effective Voltage and Current Protection Integrated Circuit for Single-Cell Li-Ion and Li-Polymer Batteries datasheet, SLUSBU9I (2024). ti.com/lit/ds/symlink/bq2970
  • MCP73831 · Microchip, MCP73831/2 Miniature Single-Cell, Fully Integrated Li-Ion, Li-Polymer Charge Management Controllers datasheet, DS20001984H. microchip.com
  • AN1149 · Microchip, Designing A Li-Ion Battery Charger and Load Sharing System With Microchip's Stand-Alone Li-Ion Battery Charge Management Controller (2008). microchip.com
  • SLUA376 · TI, Implementations of Battery Charger and Power-Path Management System Using bq2410x/11x/12x (2006). ti.com/lit/an/slua376
  • bq27441-G1 · TI, bq27441-G1 System-Side Impedance Track Fuel Gauge datasheet, SLUSBH1C (2014). ti.com/lit/ds/symlink/bq27441-g1
  • CR2032 · Energizer, CR2032 Lithium Coin product datasheet ("Max Rev Charge: 1 microampere"). data.energizer.com
  • Maxell CR warnings · Maxell, Warnings: CR Coin Type Lithium Manganese Dioxide Battery: diodes and a protective resistor against charging in backup circuits. maxell.com.tw
  • SLVA769A · TI, Understanding Undervoltage Lockout in Power Devices (2016, rev. 2018). ti.com/lit/an/slva769
  • Adafruit · Adafruit Learning System, Li-Ion & LiPoly Batteries, pages "Protection Circuitry" and "Proper Charging". learn.adafruit.com
  • Wikipedia · readable overviews: Lithium-ion battery, Battery management system, Button cell.

Checks

Check Severity Status
BAT-1 Rechargeable lithium cell without protection (overvoltage, undervoltage, overcurrent), on the pack or the board error planned
BAT-2 Charger thermistor pin (TS, NTC) floating or tied in a way that disables charging, instead of a thermistor or the documented fixed divider warning planned
BAT-3 Charger without power path while the system load sits on the battery: the load defeats termination and the cell never finishes charging warning planned
BAT-4 Primary cell (coin cell, alkaline) with a path that can charge it (a diode-less connection to a rail, a charger) error planned
BAT-5 Battery connector polarity vs the common convention for that connector (JST PH packs, barrel jacks) suggestion planned
BAT-6 Regulator or boost running from a battery without undervoltage lockout: drains the cell to zero warning planned
BAT-7 Fuel gauge sense resistor not in the leg the gauge expects (low side vs high side) suggestion planned