Skip to content

SER checks

The SER checks of the check catalogue. Each check has a page of its own: what it catches, why it matters, an example, how better_erc finds it, the usual fix and where to read more, with the test schematics that show it firing.

References used throughout:

  • SLLA272 · TI, The RS-485 Design Guide, rev. D (May 2021). Termination, failsafe biasing, unit loads, grounding. ti.com/lit/pdf/slla272
  • SLLA070 · TI, RS-422 and RS-485 Standards Overview and System Configurations, rev. D (May 2010). ti.com/lit/pdf/slla070
  • SLYT324 · TI, RS-485: Passive failsafe for an idle bus, Analog Applications Journal 1Q 2009. ti.com/lit/pdf/slyt324
  • SLOA101 · TI, Introduction to the Controller Area Network (CAN), rev. B (May 2016). ti.com/lit/pdf/sloa101
  • SLLA337 · TI, Overview of 3.3V Controller Area Network (CAN) Transceivers, rev. A (May 2025). Split termination and ground shift. ti.com/lit/pdf/slla337
  • SLLA014 · TI, Low-Voltage Differential Signaling (LVDS) Design Notes, rev. A (2000). ti.com/lit/pdf/slla014
  • TCAN1042H · TI, TCAN1042 Fault Protected CAN Transceiver with CAN FD, SLLSES7D (October 2021). Used as the typical CAN FD transceiver. ti.com/lit/ds/symlink/tcan1042h.pdf
  • SN65HVD230 · TI, SN65HVD23x 3.3-V CAN Bus Transceivers, SLOS346O (April 2018). A classic 1 Mbit/s transceiver with an RS mode pin. ti.com/lit/ds/symlink/sn65hvd230.pdf
  • ADM3050E · Analog Devices, 5.7kV rms, Signal Isolated, Basic CAN FD Transceiver, data sheet rev. D (fetched 21 Oct 2026 through a headless browser, analog.com refuses plain HTTP clients). The isolated transceiver on B125 and B135. analog.com/…/adm3050e.pdf
  • THVD1450 · TI, THVD14xx 3.3-V to 5-V RS-485 Transceivers, SLLSEY3E (May 2019). A modern RS-485 transceiver with built-in failsafe. ti.com/lit/ds/symlink/thvd1450.pdf
  • SN75176B · TI, SNx5176B Differential Bus Transceivers, SLLS101I (August 2025). The classic RS-485 transceiver without failsafe. ti.com/lit/ds/symlink/sn75176b.pdf
  • MAX3232 · TI, MAX3232 3-V to 5.5-V Multichannel RS-232 Line Driver and Receiver, SLLS410O (June 2021). ti.com/lit/ds/symlink/max3232.pdf
  • W25Q128JV · Winbond, W25Q128JV 3V 128M-bit serial flash memory with dual/quad SPI, revision M (December 2024). winbond.com/resource-files/W25Q128JV RevM 12242024 Plus.pdf
  • DS18B20 · Maxim Integrated (Analog Devices), DS18B20 Programmable Resolution 1-Wire Digital Thermometer, 19-7487 rev. 6 (July 2019; fetched through a headless browser). analog.com/…/DS18B20.pdf
  • CP2102N · Silicon Labs, CP2102N Data Sheet, rev. 1.5 (fetched through a headless browser). silabs.com/…/cp2102n-datasheet.pdf
  • AN2606 · ST, Introduction to system memory boot mode on STM32 MCUs, rev. 70 (February 2026; fetched through a headless browser). Which pins the ROM bootloader drives. st.com/…/an2606….pdf
  • esptool boot mode · Espressif, Boot Mode Selection (esptool docs, ESP32), "Automatic Bootloader". docs.espressif.com/…/boot-mode-selection.html
  • ELM MMC/SDC · ChaN, How to Use MMC/SDC, "Consideration on Multi-slave Configuration". elm-chan.org/docs/mmc/mmc_e.html
  • PJRC SPI · PJRC, Better SPI Bus Design in 3 Steps. pjrc.com/better-spi-bus-design-in-3-steps
  • ISO 11898-2:2016 · Road vehicles — Controller area network (CAN) — Part 2: High-speed medium access unit. TIA-485-A · Electrical Characteristics of Generators and Receivers for Use in Balanced Digital Multipoint Systems. TIA-232-F · Interface Between Data Terminal Equipment and Data Circuit-Terminating Equipment Employing Serial Binary Data Interchange. Cited by title.
  • Wikipedia · readable overviews: UART, Serial Peripheral Interface, CAN bus, CAN FD, RS-485, RS-232, 1-Wire, LVDS.
  • HSDD · Johnson & Graham, High-Speed Digital Design: A Handbook of Black Magic (Prentice Hall, 1993), chapter 6 (terminations).
  • AoE3 · Horowitz & Hill, The Art of Electronics, 3rd ed. (Cambridge, 2015), chapter 14 (serial buses and data links).

Checks

Check Severity Status
SER-1 USART TX connected to TX (not crossed) error planned
SER-2 SPI CS line grounded: some ICs need it to work error planned
SER-3 CAN terminator based on MOSFETs or SSRs warning planned
SER-4 LVDS without terminators error planned
SER-5 Not the whole bus is present, maybe nets shorted out ≈ SER-6 error planned
SER-6 Not the whole bus is connected to a device error planned
SER-7 CAN TX and RX crossed between MCU and transceiver (they are not crossed, unlike UART) error planned
SER-8 UART flow control mis-paired: CTS to CTS, or RTS of one side not to CTS of the other error planned
SER-9 RS-485 bus without termination at both ends (120 Ω) where this board is an end node error planned
SER-10 RS-485 without fail-safe biasing (A pulled up, B pulled down) on a transceiver without built-in fail-safe: idle bus reads noise warning planned
SER-11 RS-485 DE / ~RE without a pull to the receive state: the transceiver may drive the bus while the MCU is in reset error planned
SER-12 RS-485 A/B or CAN H/L swapped against the connector's documented pinout error planned
SER-13 CAN termination wrong for the node's place: none at a bus end, or a 120 Ω on a node in the middle warning planned
SER-14 CAN split termination (2 × 60 Ω) without the centre capacitor to ground warning runs
SER-15 CAN transceiver STB, S or EN pin floating: it stays in standby or silent mode error planned
SER-16 CAN FD data rate above the transceiver's class (a classic 1 Mbit/s transceiver on a 5 Mbit/s FD bus) warning planned
SER-17 Transceiver logic side (VIO) on a different rail than the MCU pins it talks to error planned
SER-18 SPI chip select shared by two slaves, or a slave whose MISO does not tri-state when deselected on a shared MISO error planned
SER-19 SPI slave CS without a pull-up (flash, sensor, any slave): floats during the host's reset, the slave sees commands in the noise and a second slave answers on a shared MISO warning planned
SER-20 RS-232 levels (±12 V) straight into MCU pins, no transceiver error planned
SER-21 USB-UART bridge RTS / DTR wired to boot and reset for auto-programming, or deliberately not: say which suggestion planned
SER-22 1-Wire with parasitically powered devices and only a weak pull-up: suggest a strong pull-up switch suggestion planned
SER-23 RS-485 or CAN node with no ground reference to the bus (no ground wire, no isolation), or its ground tied straight to the remote ground (loop): the standards want a resistor-separated ground or an isolated node warning planned
SER-24 RS-485 unit-load budget exceeded: nodes plus the bias network over 32 UL (256 with ⅛-UL transceivers) warning planned