Skip to content

GND checks

The GND checks of the check catalogue. Each check has a page of its own: what it catches, why it matters, an example, how better_erc finds it, the usual fix and where to read more, with the test schematics that show it firing.

References used throughout:

  • MT-031 · Analog Devices, Grounding Data Converters and Solving the Mystery of "AGND" and "DGND", tutorial MT-031 (Rev. A, October 2008): ground planes, star ground, separating analog and digital ground planes, AGND and DGND pins (fetched through a headless browser, analog.com refuses plain clients). analog.com MT-031.pdf
  • SLYT499 / SLYT512 · S. Pithadia, S. More, TI, Grounding in mixed-signal systems demystified, Part 1 and Part 2, Analog Applications Journal (1Q and 2Q 2013): split vs partitioned planes, signals crossing a split. ti.com/lit/an/slyt499, ti.com/lit/an/slyt512
  • SLLA284 · TI, Digital Isolator Design Guide, SLLA284G (July 2022, revised September 2023); §4.3 creepage distance, §4.5 reference planes. ti.com/lit/an/slla284a
  • SLLA353 · TI, Isolation Glossary, SLLA353A (October 2014, revised September 2017): VIOWM, VIORM, VIOTM, VISO, VIOSM, CIO, creepage, CTI. ti.com/lit/an/slla353
  • SLLA368 · TI, Low-Emission Designs With ISOW7841 Integrated Signal and Power Isolator, SLLA368C (May 2017, revised February 2019); §4 interlayer side 1-to-side 2 capacitor, §5 direct and capacitive connection to protection earth. ti.com/lit/an/slla368
  • Wikipedia · Galvanic isolation, Ground loop (electricity), Chassis ground.
  • Ott · H. W. Ott, Electromagnetic Compatibility Engineering (Wiley, 2009), chapter 3 (grounding), chapter 17 (mixed-signal PCB layout).
  • IEC 60384-14 · Fixed capacitors for use in electronic equipment, Part 14: Sectional specification: Fixed capacitors for electromagnetic interference suppression and connection to the supply mains (X and Y classes); by title, not fetched.

Checks

Check Severity Status
GND-1 Split grounds without an isolated circuit: warn, point to books and pages warning planned
GND-2 Suggest a Y cap between isolated grounds suggestion planned
GND-3 Analog and digital grounds joined at more than one point, or not joined at all warning runs
GND-4 Net crossing an isolation barrier: a label or power symbol of one side used on the other (GND on the isolated side) error planned
GND-5 Non-isolated part or structure spanning the barrier: a pull-up, capacitor, resistor or protection diode between the two sides, a debug header ground, a shield or a mounting hole bonded on both error planned
GND-6 Isolation rating of the isolators, transformers and Y capacitors vs the voltage the barrier must hold suggestion planned
GND-7 Connector shield or case bond not straight on the ground the enclosure asks for (grounds.enclosure), or a floating chassis net ≈ USB-4 warning runs