Check Severity Status
ANA-1 ADC input from a high impedance source without buffer warning planned
ANA-2 Sensitive signals (ADC, high impedance) next to high speed ones on a part (by pin or ball number) warning planned
ANA-3 Shunt lines to the amplifier without a filter suggestion runs
ANA-4 Current sense resistor straight to ground or power: suggest net ties suggestion runs
ANA-5 Reference or bias input (REF, VBIAS) fed from a divider: divider impedance vs the pin's input current shifts the reference warning planned
ANA-6 Op-amp input common-mode range vs the signal: a signal at a rail on a non-rail-to-rail input error planned
ANA-7 Op-amp output swing vs what the next stage needs: an output expected at 0 V on a single-supply part that stops 50 mV short warning planned
ANA-8 Op-amp input driven beyond its supply with no series resistance: phase reversal on older parts, damage on all warning planned
ANA-9 Op-amp driving a capacitive load (an ADC input, a long line) without an isolation resistor warning planned
ANA-10 Op-amp with no feedback path, or feedback into the non-inverting input (a comparator by accident) error runs
ANA-11 Unused op-amp channel left floating: wire it as a buffer to mid-rail or ground warning runs
ANA-12 Comparator on a slow or noisy signal without hysteresis suggestion runs
ANA-13 ADC input range exceeded without scaling (a 5 V signal into a 3.3 V ADC) ≈ LVL-10 error planned
ANA-14 Current sense amplifier common-mode rating below the bus it sits on (a 26 V part on 48 V) error planned
ANA-15 Sense gain times shunt drop saturates below the current that must be measured, or wastes most of the ADC range warning planned
ANA-16 Gain or filter resistors far outside the sane range for the op-amp (10 Ω loading the output, 10 MΩ against bias current) warning runs
ANA-17 Thermistor or sensor divider referenced to VDD while the ADC uses a separate reference (or the reverse): the ratio drifts with the rail suggestion planned
ANA-18 No anti-aliasing filter before an ADC on a noisy or fast source suggestion planned
ANA-19 DAC output into a load it cannot drive (low impedance, capacitance) without a buffer warning planned
ANA-20 Analog input (ADC, comparator, op-amp) above VDDA + 0.3 V, also on a 5 V-tolerant pin: tolerance is for the digital input, the analog path has its own diodes ≈ LVL-10, ANA-13 error planned
ANA-21 AC-coupled (or transformer-coupled) amplifier input with no DC return path for the bias current: the coupling capacitor charges until the amplifier saturates, hours later error runs
ANA-22 Mid-rail bias divider without a capacitor to ground: the supply noise rides on the bias suggestion runs
ANA-23 Sense path from a shunt through a copper trace or a part with high TCR (copper is 3900 ppm/°C), or sense lines taken from the power pads instead of Kelvin points ≈ ANA-4 warning planned
ANA-24 Weakest link along a chain (signal, reference, power or clock path: reference → buffer → ADC, sensor → amp → filter → ADC, LDO → reference → DAC, oscillator → PLL → converter) whose noise, offset, drift, accuracy, bandwidth, jitter, PSRR or leakage swamps what a precise part of the chain delivers; figures from part data, combined by the class figure table, no pair-specific rules ≈ PAS-40, BOM-19 warning planned
ANA-25 Over-specified part a chain cannot use: its contribution on every figure it is graded on is negligible against the rest of the chain or below what the sink resolves (lost cost) ≈ PAS-41, BOM-19 suggestion planned