Skip to content

LEAK checks

The LEAK checks of the check catalogue. Each check has a page of its own: what it catches, why it matters, an example, how better_erc finds it, the usual fix and where to read more, with the test schematics that show it firing.

These checks matter most on battery and energy-harvesting boards, where a sleep budget of a few microamps is easily eaten by one resistor. On mains or USB-powered boards most findings are reminders, not faults.

References used throughout:

Checks

Check Severity Status
LEAK-1 Resistor divider straight on a power rail, draining power all the time warning runs
LEAK-2 Pins that can't be high in some power states (go to another domain): list them even if the warning is suppressed suggestion planned
LEAK-3 NC pins: suggest setting them to analog or pulling them to cut power draw suggestion planned
LEAK-4 Resistor divider or pull through a normally closed button or switch: current flows in the rest state warning planned
LEAK-5 Indicator LED permanently on a battery rail suggestion planned
LEAK-6 Pull-up on a line that is held low in sleep (or pull-down on one held high): steady current in the low power state suggestion planned
LEAK-7 Battery measurement divider always connected: suggest a switched divider or a high-side switch ≈ LEAK-1 suggestion planned