SHORT checks

The SHORT checks of the check catalogue. Each check has a page of its own: what it catches, why it matters, an example, how better_erc finds it, the usual fix and where to read more, with the test schematics that show it firing.

References used throughout:

Checks

Check Severity Status
SHORT-1 Net shunting a known part (R, C, L, transistor...): most likely a net label collision, or a port and net label with the same name ≈ SHORT-2 error runs
SHORT-2 Accidental net name collision, e.g. on I2C: VCCa-R-R-VCCa/b, or two 0R leading to the same net error runs
SHORT-3 Non-DNM part shunting another mounted part error runs
SHORT-4 Short circuit between power and ground through low value resistor(s) error runs
SHORT-5 VDD/VCC pins shorted to GND, or GND/VEE to power nets error runs
SHORT-6 Inputs shorted to ground or power without a resistor error runs
SHORT-7 Shorted IOs: warn that they must be driven together warning runs
SHORT-8 Direct connections to battery and other high energy nets warning planned
SHORT-9 Power to ground through a forward-biased diode or a MOSFET body diode error planned
SHORT-10 Power to ground through a TVS or zener whose standoff voltage is below the net voltage error planned
SHORT-11 Two push-pull outputs on one net (output-output conflict) error runs
SHORT-12 Differential pair with P tied to N: a label typo or a wrong bus entry error runs