HS-3 Clocked bus with only some lines through a buffer¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on NET-10 |
Looks at. Bus grouping (clock and its data lines), parts in series per line.
What it catches. A synchronous bus (SPI, QSPI, SDIO, RGMII, parallel RGB, I2S) where the clock passes through a buffer, translator, divider, isolator or mux and some of its data lines do not, or pass through a different part.
Why it matters. Every part in the path adds propagation delay, a few nanoseconds for a logic translator and tens for a digital isolator. If clock and data take different paths, the skew between them comes straight off the setup or hold margin. The read direction is worse: the clock goes out through the buffer, and the slave's data comes back through another one, so the master samples late by the round trip.
Example. An SPI flash at 50 MHz (10 ns half period) behind a level translator: SCK and MOSI go through it, MISO comes back through a second channel. The MCU samples MISO on its own SCK edge, but the data was launched by the delayed SCK at the flash and delayed again on the way back; at room temperature it works, hot or with a slow batch of translators it reads garbage. The same happens when only the RGB pixel clock of an LCD gets a buffer to "clean it up".
How to check. Group the lines of each bus by peripheral pins (NET-12), follow each line to the far device (NET-10) and compare the series parts on the way. A difference in part count or type between the clock and any data line of one bus is the finding; better_erc cannot compute the timing, only point at the asymmetry.
Fix. Put every line of the bus through the same kind of part (channels of one translator package match best), lower the clock, or use the controller's sample-delay setting (QSPI and SDIO controllers often have one) and check the timing with the datasheet numbers.
References. Johnson & Graham, chapter "Clock Distribution"; SPRAAR7 §2.3 (length matching within a bus).