Severity Status Implementation
warning planned hard, depends on NET-8

Looks at. Power states, pull-ups and their rails.

What it catches. A pull-up from a switchable rail onto a net that stays in use while that rail is off: a shared interrupt or reset line, an I2C bus, a chip select.

Why it matters. With its rail off, the pull-up turns into a load: the line's high feeds the dead rail through the resistor and whatever is on that rail, so the line drags towards the rail's resting voltage. An open-drain line with its only pull-up on the dead rail simply reads low.

Example. An open-drain INT_N shared by an always-on PMIC and a sensor, pulled up with 10 kΩ to the sensor's switched +3V3_SENS: with sensors off, the line reads low, and the MCU, which wakes on INT_N low, never sleeps.

How to check. For each power state, nets used by on domains whose pull-ups (or only pull-up) go to an off rail.

Fix. Pull up to an always-on rail (the one of the line's receiver), and isolate the switched devices.

References. AN4899 §6.2 "Cross-voltage domains leakage"; catalogue I2C-19 and its detail section.