BAT-6 Regulator or boost running from a battery without undervoltage lockout¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-5, NET-7, CFG-2 |
Looks at. Regulators on the battery net, their UVLO thresholds, the cell's cut-off voltage.
What it catches. A regulator or boost converter fed from a battery whose undervoltage lockout (internal, by an EN divider, or by a protector) is below the voltage at which the cell must stop discharging, or absent.
Why it matters. A boost converter keeps running as the cell falls, drawing more and more current to hold its output, until the cell is at its own internal limit. A lithium cell taken below its cut-off (about 2.5-3.0 V per cell) loses capacity and can become unsafe to recharge; an unprotected cell stored with such a load reaches 0 V. Even with a pack protector, the protector's cut-off is the last line, not a run limit.
Example. A boost from one Li-ion cell to 5 V whose own UVLO is around 1.8 V (fine for two alkaline cells, the part's other use): on a raw cell it runs the cell down to 1.8 V. A divider on EN setting a 3.2 V start and a 3.0 V stop keeps the cell inside its range.
How to check. Regulators on a battery net (NET-5); their UVLO from part data or an EN divider (NET-7); the cell's cut-off from its chemistry or the project (CFG-2). Flag a threshold below the cut-off.
Fix. An EN-pin divider with hysteresis, a supervisor or a load switch with UVLO, or a protector whose over-discharge threshold is set at the run limit.
References. SLVA769A §1 (UVLO in battery-powered applications), §3 (hysteresis); BQ297xx §8.4.3 (over-discharge status); PIN-16 for sagging inputs in general.