BAT-1 Rechargeable lithium cell without protection¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | mid, depends on NET-7, CFG-2 |
Looks at. Battery parts and their chemistry, protection ICs and FETs on the cell, the pack's own protection (project).
What it catches. A rechargeable lithium cell (Li-ion, LiPo, LiFePO4) on the board or on a battery connector with no protection against overcharge, over-discharge and overcurrent: no protector IC with its FETs on the board, and no statement that the pack carries one.
Why it matters. A charger limits the charge voltage only while it works and only while it is the source. A shorted load, a charger fault or a load that drains the cell to zero is not stopped by anything: a shorted lithium cell delivers tens of amperes and can go into thermal runaway, and a cell discharged far below its cut-off is damaged and unsafe to charge again.
Example. A raw 18650 cell (bare, no protection board) on a board with an MCP73831 charger: the charger stops at 4.2 V, but nothing opens the circuit when a downstream regulator fails short, and nothing stops the system from draining the cell to 0 V in storage. A BQ2970 with a dual NMOS in the cell's negative lead covers all three.
How to check. Find battery parts (BT designator, battery connector class) and their chemistry from the MPN or the project; look for a part the library classes as a cell protector (NET-7) between the cell and the system. A pack with its own protection is a project fact (CFG-2): without it, report.
Fix. Use protected packs and say so in the project, or put a protector (BQ297xx class: overcharge, over-discharge, charge and discharge overcurrent, short circuit) with its two FETs on the board.
References. BQ297xx §8.4 (normal, overcharge, over-discharge and overcurrent states), §9.2 (typical application); Adafruit, "Protection Circuitry" (raw cells are not protected); Wikipedia, Battery management system.