Skip to content

BOOT-5 No way to force the ROM bootloader on a board updated in the field

Severity Status Implementation
suggestion planned mid, depends on NET-12

Looks at. The part's boot entry pins, buttons and connectors.

What it catches. A controller with a ROM bootloader whose entry condition (a boot pin, QSPI_SS low, GPIO0 low) cannot be reached from outside: no button, no jumper, no header pin, no test pad.

Why it matters. Firmware that boots and hangs before its own update code runs can only be fixed through the ROM. Without a way to force it, every such board needs a debug probe or a return.

Example. B200A has no BOOT button, but BOOT_EXT on header J103 pin 5 goes through 255 Ω and 1 kΩ to QSPI_SS: shorting it to the GND pin next to it while plugging in starts the RP2350's USB bootloader (B200A hardware reference §3). The RP2350 reference design uses a button on QSPI_SS through 1 kΩ (RP2350 HW §3.1, §5.4).

How to check. The ROM entry pin of each programmable part (NET-12); require a path to a switch, jumper, connector or test point, through at most a resistor.

Fix. A button or a pad pair on the boot pin, through a resistor so it can override the pin's normal use.

References. RP2350 HW §3.1, §5.4; ESP32 §3.1; AN2606 §4.1.