Skip to content

BOOT-6 ROM bootloader interface not reachable from outside with the firmware dead

Severity Status Implementation
error planned hard, depends on NET-8, NET-10, NET-12, NET-13

Looks at. Bootloader interfaces, what lies on the way out.

What it catches. The ROM bootloader's interface (USB DFU, a UART, CAN) reaching the connector only through a part that firmware must configure first: a hub, a mux, a level shifter, a PHY.

Why it matters. The ROM runs with the board in its reset defaults. Any part between the controller and the outside that needs configuration, a GPIO level or a released reset stays in its default, and the ROM talks into nothing (LOGIC-5).

Example. B153A: the STM32G0B1's USB goes through hub U301, strapped for SMBus configuration (USB251xB Table 5-1) and held in reset by a pull-down after every MCU reset. The ROM's USB DFU runs and never reaches the host. B125B had the same shape with a ULPI PHY: the change list for rev B says to keep it in reset so the built-in bootloader works.

How to check. From each bootloader interface (NET-12), follow the signal to the connectors (NET-10, across boards with NET-13) and check every part on the way in its reset-default state (NET-8): a switch's default position, a hub's strap mode, a translator's OE pull.

Fix. A path that works with the controller in reset: a default-on mux position, a strap that makes the hub work alone, or a separate connector for the ROM's interface.

References. AN2606 §4.3, §50.1; USB251xB §5.3; B153 and B125 rev B change lists.