Skip to content

DRV-13 Low-side switch under a load with ground-referenced signals

Severity Status Implementation
warning planned mid, depends on NET-5, NET-7

Looks at. The load's ground pin, its other connections.

What it catches. An N-channel FET or NPN switching the ground of a load (a module, a sensor, a display) that also has signal lines to the rest of the board, referenced to the main ground.

Why it matters. With the switch off, the load's ground is no longer ground: it floats up towards its supply through the load's own circuitry. Its signal pins then sit far above their ground, the signals from the board drive its clamps (BKF-2), and its outputs push current back into the board's inputs. Low-side switching is fine for a plain load (an LED, a motor); it does not work for anything that talks to the board.

Example. A GPS module whose GND is switched by an NMOS to save power, with its UART on the MCU: with the switch off, the module's ground rises to about 3 V through its internals, its TX pin drives the MCU's RX near 3.3 V, and the MCU's TX powers the module through its RX clamp.

How to check. Ground pins of parts whose net is the drain of a low-side switch (not a ground), where the same part has other pins on nets shared with the board.

Fix. Switch the supply on the high side, or use a load switch with power-off-safe IO isolation.

References. SLVA716 §6 "NMOS Discrete Circuits"; catalogue BKF-2, DRV-2.