Skip to content

DRV-8 Open-loop flyback with no minimum load on its output

Severity Status Implementation
error planned mid, depends on NET-5, CFG-5

Looks at. Converter type (no feedback), the output load.

What it catches. A flyback or transformer converter without feedback from the output (primary-side regulated, or a fixed-ratio transformer driver) whose output has no resistive load or zener clamp to keep it in range at no load.

Why it matters. Without feedback the output voltage depends on the load. At no load the leakage energy charges the output capacitor with nothing to discharge it, and the voltage rises far above nominal: the next part on that rail (an LDO, an isolated transceiver) sees more than its rating as soon as the load is light or disconnected.

Example. An SN6501 transformer driver making an isolated supply for a CAN transceiver with no LDO after it: the voltage that is right under load rises towards VIN × n (the turns ratio) when the bus idles. The datasheet strongly advises an LDO for this reason, and that LDO's input rating must cover the no-load voltage.

How to check. Converters of an open-loop class (library), or a flyback controller with no feedback divider or optocoupler from the output; look for a resistor or zener on the output.

Fix. A minimum-load resistor or a zener clamp at the output, sized from the datasheet's no-load voltage; or a regulated topology.

References. SN6501 §8.2.2 "Detailed Design Procedure" (LDO strongly advised), §8.2.2.2 "LDO Selection" (no-load output VIN-max × n); Wikipedia, Flyback converter "Operations" (primary-side sensing needs a minimum load).