Skip to content

IO-6 High impedance nets acting as touch buttons

Severity Status Implementation
warning runs in better_erc easy, depends on IMP-1

Data it needs: graph, part classes, rails. Folds in: IO-1.

Looks at. Connectivity, pin types.

What it catches. A high-impedance input net that reaches something a finger, a cable or a probe can touch: a connector, a test pad, a button or a long trace, with no pull and no driver.

Why it matters. A floating input with a few pF to the outside world is a capacitive touch sensor: touching the connector, bringing a hand close, or ESD flips the level. The bug reports read "the board resets when I touch it".

Example. A header pin EXT_TRIG wired straight to an MCU input with only a 100 Ω series resistor: with no cable plugged, a finger near the header triggers acquisitions.

How to check. IO-1 nets that reach a connector, test point or switch part (IMP-1 part classes).

Fix. A pull (10-100 kΩ) on the board side, and ESD protection if it leaves the enclosure.

References. SCBA004E §1; AN4899 §6.1 (noise on unconnected inputs).

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only IO-6 reports on it.

io-6_touch_inputs

The test schematic io-6_touch_inputs The test schematic io-6_touch_inputs

  warning    IO-6 #4d5      U1.5 (A3) on /TOUCH_FAR float and TP3 can touch the net: a touch sensor, it flips with a finger or ESD (also IO-1)
                            net /TOUCH_FAR, pin U1.5
                            fix: a pull (10-100 kΩ) on the board side, and ESD protection where it leaves the enclosure
  warning    IO-6 #qcy      U1.3 (A1) on /TOUCH_TP float and TP1 can touch the net: a touch sensor, it flips with a finger or ESD (also IO-1)
                            net /TOUCH_TP, pin U1.3
                            fix: a pull (10-100 kΩ) on the board side, and ESD protection where it leaves the enclosure

IO-6 also fires on the test schematics of other checks: short-12_pair_halves_tied.