Skip to content

IO-7 Button to ground with a pull-down, or button to power with a pull-up

Severity Status Implementation
error runs in better_erc easy, depends on NET-5

Data it needs: graph, part classes, rails, values. Folds in: IO-8.

Looks at. Switch parts, resistors to rails.

What it catches. A switch whose closed state pulls the net to the same level the resistor already holds it at.

Why it matters. The button does nothing: pressed and released read the same. It is a copy error (a pull-up footprint wired to GND) that the ERC never sees, because every pin is connected.

Example. SW1 between BTN and GND, R12 10 kΩ from BTN to GND as well: the input reads low forever.

How to check. For each switch, the rail on its far side (NET-5) must differ from the rail of every pull on the input side.

Fix. Pull towards the other rail.

References. Wikipedia, Pull-up resistor; Wikipedia, Switch (contact bounce).

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only IO-7 reports on it.

io-7_button_pulls

The test schematic io-7_button_pulls The test schematic io-7_button_pulls

  error      IO-7 #3a6      SW1 pulls /BTN_A to GND and R1 pulls it there too: the button does nothing (also IO-8)
                            net /BTN_A, part SW1
                            fix: pull towards the other level
  error      IO-7 #s6q      SW2 pulls /BTN_B to +3V3 and R2 pulls it there too: the button does nothing (also IO-8)
                            net /BTN_B, part SW2
                            fix: pull towards the other level