Skip to content

TEST-6 Clock, reset or enable net without a test point

Severity Status Implementation
suggestion planned mid, depends on NET-7

Looks at. Clock, reset and enable pins (by name or role, NET-7), test points.

What it catches. Clock nets (crystal outputs, clock buffers, MCO), reset nets and enable or power-good nets with no test point.

Why it matters. "Does the oscillator run, is reset released, is the regulator enabled, is power-good high" are the questions of a board that does nothing; each is one probe touch with a test point and a hunt without one. A fixture can also hold a part in reset through the reset test point.

Example. B135B's test plan measures XOUT on TP305 with a frequency counter and triggers a reset through TP209 on ~H7_RST to check that the firmware reboots; B200A puts the buck's power-good on TP1602.

How to check. Nets on pins of clock, reset or enable role (names like XOUT, CLKOUT, MCO, RST, EN, PG, or pin roles from NET-7) with no test point.

Fix. A test point on each; for crystals, on the output side through a small series resistor or on a clock output the MCU can enable, so the probe's capacitance does not stop the oscillator.

References. B135B test plan (TP305 XOUT, TP209 reset); B200A schematic review §2 (TP1602 PG).