Skip to content

BOM-13 Variant: a part's DNP flag disagrees with its per-variant fields

Severity Status Implementation
warning planned mid, depends on IMP-1 (variant data from the schematic), IMP-8

Looks at. Variant data from the schematic (KiCad 10 design variants), BOM per variant.

What it catches. Two kinds of variant confusion: a part whose base DNP flag says one thing while its per-variant override or fields say another (a DNP part with a variant MPN, a fitted part whose variant value is empty), and a BOM or placement file built from the base DNP flags instead of a variant.

Why it matters. Variants live as overrides on top of the base design. Tools that read only the base flag (a plain netlist, an older BOM export, an importer) see neither variant correctly: they list parts that no variant fits, or miss parts every variant fits. The assembler builds what the file says.

Example. B153A has Main and Plus variants; R211/R212 are DNP in both, but the old BOM CSV and the parts-store import showed them placed. Its hub U301 still carries 18 alternate MPNs mixing the 2-port USB2512B and the 4-port USB2514B in one line, so a variant BOM could get the wrong hub; the change list asks for per-variant MPNs and per-variant BOM exports.

How to check. Read the variant overrides from the schematic, build each variant's fitted list, compare with the base flags and with per-variant fields; any BOM or PnP file handed in can be checked against the variant it claims.

Fix. Keep variant data in the variant mechanism, not in base flags and comments; export BOM and placement per variant.

References. KiCad variants ("Understanding design variants", "Generating variant-aware outputs"); B153A schematic review §9; B153 rev B change list (per-variant MPNs and BOM export).