Skip to content

BOM-6 "Calculate later" part mounted

Severity Status Implementation
error runs in better_erc easy, depends on IMP-6

Data it needs: graph, values. Folds in: BOM-5.

Looks at. Value field, DNP flag.

What it catches. A part with a placeholder value that is not DNP: it will be placed.

Why it matters. A placeholder on a DNP part is harmless (an option for later); on a mounted part the assembler must put something there. This is the version of BOM-5 that breaks a build.

Example. A divider resistor ?? mounted in the base variant: the first article comes back with a 0 Ω, the rail it sets comes up at the regulator's reference voltage.

How to check. BOM-5 findings filtered by the part's DNP flag (and its per-variant flags, BOM-13).

Fix. Decide the value, or make the part DNP.

References. FEATURES.md (BOM-5, BOM-6); KiCad variants (DNP per variant).

BOM-6 also fires on the test schematics of other checks: bom-10_values.