Skip to content

LIB-13 Units of one part disagree

Severity Status Implementation
warning planned mid, depends on TOOL-3, IMP-1

Looks at. Per-unit fields and connections from the schematic.

What it catches. A multi-unit part (a quad op-amp, a hex inverter, a dual MOSFET) whose units carry different footprints or values, or whose shared power pins are connected to different nets in different units.

Why it matters. The units are one physical part. If unit A says TLV9064 and unit C says TLV9062, the BOM gets one of them and half the schematic was designed for the other; if the footprint differs, the netlist exporter picks one and the other unit's assumption is silently lost. Shared power pins on two nets short the nets through the part (or, with hidden pins, connect two rails by name).

Example. A 74HC14 drawn with its power on every unit by hidden pins: units A to E on +3V3, unit F copied from another sheet where the hidden pin's net was +5V. The netlist joins +3V3 and +5V through the part's VCC pin.

How to check. Read the per-unit fields from the schematic (the .kicad_sch reader of TOOL-3) and compare footprint and value across units; from the netlist, check that every shared pin has one net. KiCad's own ERC checks all three ("Units of same symbol have different values", "Different footprint assigned in another unit of the symbol", "Different net assigned to a shared pin in another unit of the symbol"); better_erc repeats them for netlists from other tools.

Fix. Set fields on the symbol, not per unit; draw shared power pins in a separate power unit (KLC S3.8) instead of hiding them in each unit.

References. KiCad ERC "Conflicts ERC checks"; KLC S3.8 (multi unit symbols), S4.6 (hidden pins).