LIB-29 Placed symbol carrying a ki_ field¶
| Severity | Status | Implementation |
|---|---|---|
| warning | runs in better_erc | easy |
Data it needs: graph.
Looks at. The schematic's placed symbols.
What it catches. A placed symbol with a field whose name starts with ki_ (ki_fp_filters, ki_keywords, ki_description, ki_locked). Fields inside the library symbol (lib_symbols) never count.
Why it matters. These are properties of the library symbol. On a placed symbol they are ordinary fields, so KiCad's DRC schematic parity reports "Missing symbol field ki_fp_filters in footprint" (footprint_symbol_field_mismatch). Update PCB from Schematic never clears it, because KiCad treats a footprint field of that name as its own internal property.
Example. (property "ki_keywords" ...) and (property "ki_fp_filters" ...) as direct children of a placed (symbol (lib_id ...)).
How to check. The placed symbol's field names. An empty field is not seen: the importer drops empty fields.
Fix. Delete the field in Symbol Properties on the placed symbol, then Update PCB from Schematic.
References. None.
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only LIB-29 reports on it.
lib-29_placed_ki_fields¶
warning LIB-29 #vfe U2 carries the fields ki_fp_filters, ki_keywords: a `ki_` field belongs only in the library symbol, and on a placed symbol KiCad's schematic parity reports it as missing in the footprint (footprint_symbol_field_mismatch), which Update PCB from Schematic never clears
part U2
fix: delete the field in Symbol Properties on the placed symbol (the library symbol keeps it), then Update PCB from Schematic
warning LIB-29 #05g U3 carries the field ki_description: a `ki_` field belongs only in the library symbol, and on a placed symbol KiCad's schematic parity reports it as missing in the footprint (footprint_symbol_field_mismatch), which Update PCB from Schematic never clears
part U3
fix: delete the field in Symbol Properties on the placed symbol (the library symbol keeps it), then Update PCB from Schematic