LIB-30 Placed symbol whose mx3: Datasheet link does not reference its MPN fields¶
| Severity | Status | Implementation |
|---|---|---|
| warning | runs in better_erc | easy |
Data it needs: graph.
Looks at. The schematic's placed symbols.
What it catches. A placed symbol whose Datasheet is an mx3: link (mx3:${Mpn1} ${Mpn2}) that references an MPN field the symbol has no field for, or does not reference an MPN field the symbol has. A field left empty counts as had. A Datasheet that is a vendor URL, empty or ~ is never looked at; a literal part number in the link names no field.
Why it matters. KiCad has no wildcard over fields, so the link names each MPN field by hand. A reference to a field the symbol lacks shows unresolved (${Mpn5}) and Show Datasheet passes it on as text. A field added later (Mpn2 after the link was written) goes unnamed, and its part number never reaches the document lookup.
Example. mx3:${Mpn1} ${Mpn2} ... ${Mpn12} on a symbol with Mpn1 to Mpn4 and an empty Mpn12; mx3:${Mpn1} on a symbol that also has Mpn2.
How to check. The ${Name} references of the link against the placed symbol's field names, any case. Only MPN fields count (Mpn, Mpn1, MPN_2, the names BOM checks read as MPN fields); other references (${Value}) are not looked at.
Fix. Close the schematic in KiCad and run berc fix datasheet-links --write. Each stale link becomes mx3: and a reference to each MPN field, in field order. The symbol's copy in lib_symbols takes the library symbol's Datasheet. Fix the library first (kilib lint --rule datasheet-link --write in kicad-library).
References. kicad-library LIB-39; mx3 docs/kicad-datasheet.md.
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only LIB-30 reports on it.
lib-30_datasheet_link¶
warning LIB-30 #ck2 U2's Datasheet `mx3:${Mpn1} ${Mpn2} ${Mpn3} ${Mpn4} ${Mpn5} ${Mpn6} ${Mpn7} ${Mpn8} ${Mpn9} ${Mpn10} ${Mpn11} ${Mpn12}` references ${Mpn5}, ${Mpn6}, ${Mpn7}, ${Mpn8}, ${Mpn9}, ${Mpn10}, ${Mpn11} the symbol has no field for (KiCad shows them unresolved)
part U2
fix: close the schematic in KiCad and run `berc fix datasheet-links --write`: each link becomes `mx3:` and a reference to each MPN field, and the lib_symbols copy takes the library's Datasheet
warning LIB-30 #s22 U3's Datasheet `mx3:${Mpn1}` misses ${Mpn2} the symbol has, so their part numbers are never looked up
part U3