Skip to content

BKF-1 Power backfeed through IO

Severity Status Implementation
error planned hard, depends on NET-8, NET-7

Looks at. Power states (NET-8), pin data (Ioff).

What it catches. An output of a powered domain driving an input of a domain that can be off, where the input has no power-off protection; the suggestion is a buffer whose inputs and outputs are rated for that (Ioff, partial power down).

Why it matters. Most CMOS inputs have a clamp diode to their own VCC. With that VCC off, a high on the input forward-biases the diode and the driver supplies the whole dead domain through it: the rail rises to the high level minus a diode drop, parts on it start in an undefined state, and the driving pin sources milliamps it was never sized for. When the rail is switched on again, a part that started half-way may not reset.

Example. An MCU's UART TX into a GPS module on a switched +3V3_GPS rail: with the GPS off, TX idles high and lifts the GPS rail to up to a diode drop below 3.3 V through the module's RX clamp. The module never sees a clean power-on and comes up without a fix until the whole board is power-cycled.

How to check. For each power state (NET-8), nets that join a driving pin in an on domain to an input pin in an off domain, where the input's part has no Ioff rating (NET-7, library).

Fix. A buffer with Ioff (74LVC1G125, 74LVC1G07 class) powered from the receiving side's rail, or drive the pin low (or high-impedance) before the rail goes off (LEAK-2).

References. SZZA036 §4.6.20 "Ioff Input/Output Power-Off Leakage Current" (and the families that have it), §4.4.2 "Input Voltage, VI" (clamp diodes to VCC); SSZTAP0; SLAA689 §1 "Important Side Effects of the ESD Diodes During Power Cycling".