BKF-6 Backfeed through internal IC structure

Severity Status Implementation
warning planned judgement, depends on CFG-5

Looks at. Per-part knowledge of internal paths between supply pins.

What it catches. Paths inside a part between two of its supply or IO domains that the datasheet documents beyond plain IO protection diodes: supply ordering rules, internal diodes between VCCA and VCCB, a VIO that powers part of the core, a battery pin that feeds the main supply.

Why it matters. These are written in a datasheet's power-supply or layout section in prose, not in a table, so they are invisible to a generic check. When the board breaks such a rule, the part feeds one supply from the other or starts in an undefined state, and the failure looks like a part fault.

Example. A TXS0102 requires VCCA ≤ VCCB and asks for OE to be held low until both rails are stable. Wired the other way round (VCCA = 3.3 V, VCCB = 1.8 V, because the MCU happened to sit on the A side), the part is outside its rules and nothing in the netlist says so.

How to check. Part rules in the database (CFG-5), each a condition on the supply nets of that part; better_erc can list parts with several supply domains as candidates, the rule itself comes from reading the datasheet.

Fix. Wire the part as its datasheet requires; where it cannot be, isolate the domain or sequence the rails.

References. TXS0102 §8.3 "Power Supply Recommendations" (VCCA ≤ VCCB, OE held low until both supplies are stable).