BKF-8 I2C device on a rail that can be off

Severity Status Implementation
warning planned hard, depends on NET-8, NET-4

Looks at. Power states, the I2C buses.

What it catches. A device on an I2C bus whose supply rail can be off while the bus is on. The backfeed checks (BKF-2) find the same path in general; this is the bus-specific form with the I2C consequences.

Why it matters. The off device's SCL/SDA clamps hold both lines at about one diode drop above its dead rail, so the whole bus stays low and every other device becomes unreachable: an off sensor kills the always-on RTC. The I2C page has the full story under I2C-11.

Example. A board-ID EEPROM on a switched +3V3_PERIPH rail sharing the bus with the always-on RTC and PMIC: with peripherals off to save power, the RTC alarm can no longer be read or set.

How to check. Devices on each bus (NET-4) whose rail is off in a state where the pull-up rail is on, unless their bus pins are fail-safe.

Fix. Move the device to an always-on rail, or behind a bus switch or buffer that opens with its rail.

References. Catalogue I2C-11 and its detail section; SZZA036 §4.6.20 (Ioff parts are the exception).