Skip to content

CLK-8 Crystal load capacitors vs the crystal's CL

Severity Status Implementation
warning planned mid, depends on NET-7

Looks at. Crystal CL, capacitor values, stray estimate.

What it catches. Load capacitors that do not give the crystal its specified load capacitance CL.

Why it matters. A crystal oscillates at its nominal frequency only with the load it was cut for; a wrong load pulls it by tens of ppm per pF, and a much too large one lowers the oscillator's gain margin until it does not start (AN2867 §3.3-3.4). The catalogue's rule of thumb C1 = C2 ≈ 2·CL − Cstray uses the stray per pin; with AN2867's total stray Cs it reads CL = C1·C2/(C1 + C2) + Cs, so C1 = C2 = 2·(CL − Cs).

Example. B200A's 12 MHz RP2350 crystal follows Raspberry Pi's design: CL = 10 pF, 15 pF capacitors, about 3 pF stray: 7.5 + 3 = 10.5 pF (RP2350 HW §4). Fitting 22 pF "because the other crystal had them" gives 14 pF, 4 pF too much, which pulls the crystal tens of ppm low.

How to check. CL from the crystal's part data (NET-7), capacitor values from the netlist, stray from the part (pin capacitance) plus a default for the PCB; report the computed CL and the deviation.

Fix. Recompute the capacitors; confirm on the board by measuring the frequency (AN2867 §4.2 step 2).

References. AN2867 §3.3, §4.2; RP2350 HW §4; Wikipedia, Pierce oscillator.