DRAW-30 Several power or ground symbols of one rail on one pin group of a part, instead of the pins wired together to one symbol

Severity Status Implementation
suggestion runs in better_erc mid, depends on NET-21, NET-26

Data it needs: drawing geometry.

Looks at. The schematic drawing (geometry).

What it catches. A pin group (pins of one net next to each other on one side of a part's body) with more than max_symbols_per_rail (default 1) power or ground symbols of that net attached, each directly or through a stub that touches no other part. Two groups of one part with a symbol each are fine: whether they should share one is the routing cost's call (DRAW-40).

Why it matters. A row of identical ground symbols under one IC is noise; wiring the pins together says "all ground pins to ground" once.

How to check. Walk from each power symbol along its wires to the pins it reaches; count, per part and net, the symbols whose wire reaches only that part. Decoupling capacitors and other two-pin parts are not counted against the IC (they keep their own symbols).

Scope. At most DRAW-30.max_symbols_per_rail (default 1) symbols of one rail per pin group of a part.

Settings

Set them in the project file under [checks."DRAW-30"], or for one run with --set DRAW-30.NAME=VALUE.

Setting Default Meaning
DRAW-30.max_symbols_per_rail 1 power or ground symbols a pin group may have

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only DRAW-30 reports on it.

draw-30_symbols_per_pin_group

The test schematic draw-30_symbols_per_pin_group The test schematic draw-30_symbols_per_pin_group

  suggestion DRAW-30 #vfw   U1 pins 1, 2, 3 have 3 GND symbols, from x 66.04 y 72.39
                            sheet /, item U1 pins 1, 2, 3
                            fix: wire the pins together to one symbol