Skip to content

DRAW-44 Two sections of a sheet closer than the section gap

Severity Status Implementation
suggestion runs in better_erc hard, depends on NET-26

Data it needs: drawing geometry.

Looks at. The schematic drawing (geometry).

A section is a heading (bold text of drawing.heading_size), its grouped parameter box, and the parts, power symbols and labels nearest below and right of that heading, up to drawing.section.reach left of it; wires run between sections and are left out. Two section boxes less than drawing.section_gap apart are a finding.

Settings

Set them in the project file under [checks."DRAW-44"], or for one run with --set DRAW-44.NAME=VALUE. A name that starts with drawing. is shared by several checks and is set under that name alone.

Setting Default Meaning
drawing.section_gap 10 mm gap that separates two sections
drawing.heading_size 2.54 mm height of a section heading; larger bold text is a title
drawing.section.reach 5.08 mm how far left of its heading a section's parts may stand

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only DRAW-44 reports on it.

draw-44_section_gap

The test schematic draw-44_section_gap The test schematic draw-44_section_gap

  suggestion DRAW-44 #mm6   sections First (x 30.48..44.09 y 24.82..60.96) and Second (x 50.8..64.47 y 24.82..60.96) are 6.71 mm apart, less than 10
                            sheet /, item text "First", item text "Second"
                            fix: move the sections apart