SHORT-8 Direct connections to battery and other high-energy nets¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-5, CFG-2 |
Looks at. Battery and high-energy nets (project data).
What it catches. Parts connected straight to a battery or another source that can deliver a large current (a bench supply input, a vehicle 12 V, a supercap), with no fuse, PTC, current limit or series resistance in between.
Why it matters. A battery does not current-limit. A short anywhere on a net tied straight to it (a cracked MLCC, a solder bridge, a probe slip) has hundreds of amps available until something burns open, usually a trace or the cell. Pull-ups, dividers and decoupling caps straight on the battery net are each such a point.
Example. A Li-ion pack with a 10 µF 0805 MLCC straight across the cell terminals and no protection IC in front: a flex crack in that capacitor shorts the cell, the board chars before the cell's own protection reacts.
How to check. From the battery net (named, a battery or connector part, or a project setting) list all parts connected before the first fuse, PTC or protection switch.
Fix. A fuse or protection IC right at the source, and everything else after it; high-value series resistors for sense lines.
References. SLVA139 (protection right at the battery); catalogue PIN-4 (no overcurrent protection on an input).