Skip to content

SHORT-11 Two push-pull outputs on one net

Severity Status Implementation
error runs in better_erc easy, depends on netlist (NET-7 for pins whose type the symbol gets wrong

Data it needs: graph, fitted parts.

Looks at. Pin types (output vs open-drain, tri-state).

What it catches. A net with two or more pins that are push-pull outputs, with no series resistor between them.

Why it matters. When they disagree, one pulls high and the other low: tens of milliamps flow from rail to ground through both output stages, the net sits at an undefined voltage, and both drivers heat or degrade. Tri-state and open-drain outputs are made to share a net; push-pull ones are not.

Example. An Ethernet PHY's 50 MHz REF_CLK drawn with both a crystal oscillator and the MCU's MCO pin on it, one of the two meant as an assembly option and neither marked DNP: two clocks of slightly different frequency beat against each other, the net spends part of every cycle in contention, and the PHY loses link at random.

How to check. Pin types per net from the netlist; outputs of type "output" (not tri-state, not open collector) counted per net, with series resistors breaking the count (NET-10).

Fix. Make one of them open-drain or tri-state, combine through a gate, or separate them with a series resistor so a conflict is limited.

References. SDYA009 §7 "Bus Contention" (Figure 26, Table 4); KiCad "ERC violation severity and pin conflicts map" (output to output is an error by default); Wikipedia, Bus contention; Wikipedia, Open collector "Wired logic".

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only SHORT-11 reports on it.

short-11_output_conflict

The test schematic short-11_output_conflict The test schematic short-11_output_conflict

  error      SHORT-11 #tg7  /REF_CLK: push-pull outputs U1.1 (MCO1), X1.3 (OUT) drive one net
                            net /REF_CLK, part U1, part X1, pin U1.1, pin X1.3
                            fix: make one open-drain or tri-state, combine through a gate, or separate them with a series resistor; an assembly option is DNP

SHORT-11 also fires on the test schematics of other checks: name-4_uart_names, rail-1_unpowered_pins.