Skip to content

SHORT-10 TVS or zener with standoff voltage below the net voltage

Severity Status Implementation
error planned mid, depends on NET-5, CFG-2

Looks at. TVS standoff / zener voltage (part data), net voltage.

What it catches. A TVS whose reverse standoff voltage (VRWM) or a zener whose zener voltage is below the highest normal voltage of the net it protects.

Why it matters. A TVS is meant to be an open circuit up to VRWM and conduct only during a transient. Below the net's working voltage it conducts all the time: it heats, drags the rail down, or burns open and leaves the line unprotected. A zener clamp below the signal's high level clips every high.

Example. A 5 V TVS (SMAJ5.0A, VRWM 5 V) on a USB-C VBUS that negotiates 9 V or 20 V with USB PD: at 9 V it conducts heavily, the source sees a short and drops the contract, or the TVS fails short. On B153A the header IO lines clamp 3.3 V signals with 5V6 zeners behind 255 Ω: above the working level, so they stay open in normal use.

How to check. Standoff or zener voltage from the part (MPN decoding or library data) against the net's maximum voltage (NET-5, or the project setting for connector nets and PD rails).

Fix. Pick VRWM at or above the highest working voltage (and the clamp voltage below what the protected part survives); for PD VBUS a 24 V TVS class part.

References. SSZB130 §2.1 "Working Voltage (VRWM)"; ROHM TVS, point 1 "Selection with consideration of the voltage on the wiring"; Wikipedia, Transient-voltage-suppression diode "Characterization".