I2C-11 Back-powered I2C device¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | hard, depends on NET-7, NET-8 |
Looks at. Power states (NET-8), device supply rail, fail-safe data of the part.
What it catches. A device on the bus whose supply can be off in some power state while the bus stays powered, and whose SCL/SDA pins are not fail-safe (Ioff-rated) inputs.
Why it matters. An unpowered CMOS input has its ESD diode to VDD forward-biased by the bus high: the device powers itself through the diode to ~0.6 V and clamps both lines there, below VIL for everyone else. The entire bus is dead until that one device gets power. The design "works" when everything is on, and fails exactly in the low-power state it was meant to support.
Example. A display controller on a switchable +3V3_DISP rail sharing the bus with the always-on PMIC and RTC. Display off: no RTC access, the system cannot wake on alarm.
How to check. For each power state, devices on the bus whose rail is off while the pull-up rail is on; the part is exempt only if the library says its bus pins are fail-safe (PCA9306-class switches, buffers with Ioff, isolators).
Fix. Put the device behind a bus switch that is off with its rail, or on an isolated segment with its own pull-ups from the same rail (I2C-18, I2C-19), or keep it powered.
References. SCPA054 §3 (bus isolation, hot-swap); UM10204 §3.1.16 (bus clear, which does not help here); catalogue BKF-2 for the general backfeed case; our "I2C in the wild" notes §1.