DBG-10 Many things on one power net: suggest splitting with a 0R before each power input¶
| Severity | Status | Implementation |
|---|---|---|
| suggestion | runs in better_erc | easy, depends on NET-5 |
Data it needs: graph, part classes, rails.
Looks at. Rails (NET-5), power input pins per part.
What it catches. A rail that feeds many parts' supply pins with no 0 Ω, ferrite or jumper between the rail and any of them.
Why it matters. When the rail is shorted or draws too much, there is no way to find the culprit short of lifting parts; with a 0 Ω per branch each load can be isolated and its current measured. The same footprint also becomes the place for a ferrite if one branch turns out noisy, and lets one block be left unpowered in a variant.
Example. On B200A the analog buffer rail +5V0_FLT had no source: probably a ferrite or 0 Ω from +5V0_USBIN went missing, and the rework had to add one between two pads that were never there (RAIL-5). A design with a branch footprint per block makes that both visible in the schematic and trivial to bodge.
How to check. Count supply pins of distinct parts on each rail; above a threshold (say five parts, or several functional blocks) with no series part per branch is a finding.
Fix. A 0 Ω (or ferrite, or solder jumper) at the start of each block's branch.
References. Ott, Electromagnetic Compatibility Engineering, chapter 11 (decoupling and power distribution); B200A schematic review §0.
Settings¶
Set them in the project file under [checks."DBG-10"], or for one run with --set DBG-10.NAME=VALUE.
| Setting | Default | Meaning |
|---|---|---|
DBG-10.max_parts |
5 | the most parts a rail feeds directly before a branch footprint is suggested |
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only DBG-10 reports on it.
dbg-10_crowded_rail¶
suggestion DBG-10 #qmq +3V3 feeds 6 parts directly (U1, U2, U3, U4, U5 and U6): no branch can be isolated or measured
net +3V3
max_parts = 5 (derived DBG-10 default)
fix: a 0 Ω (or ferrite, or solder jumper) at the start of each block's branch
DBG-10 also fires on the test schematics of other checks: clk-18_clock_fan_out, eth-3_mdio_pull_up, logic-3_fan_out, logic-8_polarity, mem-8_ddr_zq, mux-1_swapped_signals, rail-18_parallel_regulators.