Skip to content

DBG-16 No firmware-driven LED (heartbeat), only power LEDs

Severity Status Implementation
suggestion runs in better_erc easy, depends on netlist (NET-10 for LEDs driven through a transistor

Data it needs: graph, part classes. Folds in: DBG-3.

Looks at. LEDs and what drives them (MCU pin, rail).

What it catches. A board whose LEDs all hang on rails: none is driven by an MCU pin.

Why it matters. A power LED says the rail is up, not that the firmware runs. A heartbeat LED blinking from the main loop or a timer shows a hang, a reset loop (blink pattern restarts) and a hard fault at a glance, and is the first thing a bring-up firmware toggles.

Example. B153A has a red and a green LED on PF0 and PF1 (both on timer channels for PWM): the firmware shows its state without a probe. A board with only a "3V3" LED shows the same glow whether the firmware runs or sits in a hard fault.

How to check. LEDs whose resistor chain ends on an MCU GPIO (directly, or through a transistor with NET-10); none is a finding when a programmable part exists.

Fix. One LED on a free GPIO, ideally one with a timer output.

References. B153A schematic review §11 (LED pins, timer channels).

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only DBG-16 reports on it.

dbg-16_heartbeat_led

The test schematic dbg-16_heartbeat_led The test schematic dbg-16_heartbeat_led

  suggestion DBG-16 #61p    no LED is driven by U1: D1 and D2 only show power
                            part D1, part D2
                            fix: one LED on a free GPIO, ideally one with a timer output

DBG-16 also fires on the test schematics of other checks: logic-7_open_drain.