DBG-5 No error flag LEDs when flags aren't routed to IOs¶
| Severity | Status | Implementation |
|---|---|---|
| suggestion | planned | mid, depends on NET-7 |
Looks at. Fault and status outputs of parts (pin roles, NET-7).
What it catches. Fault and status outputs (FAULT, nFLT, PG, CHG, STAT, ALERT) that go neither to an MCU pin nor to an LED: left open, or only pulled up.
Why it matters. A load switch that trips, a charger that stops on a timer fault, a regulator that never reaches power-good: the part knows and says so on a pin, and nobody listens. Without a GPIO or an LED the failure looks like "the board does nothing" and is found with a scope after an hour.
Example. A TI BQ24075 charger whose open-drain CHG and PGOOD outputs, meant to drive LEDs, are left unconnected: a battery that never charges cannot be told from a charger that was never powered.
How to check. Pins of fault or status role (from the library, NET-7, or by name) whose net reaches no MCU pin, no LED and no connector.
Fix. Route the flag to a GPIO; when pins are short, put an LED (open-drain flags can sink it directly) or at least a test point.