ETH-1 Magnetics centre taps terminated for the wrong PHY type¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | mid, depends on NET-7, NET-5 |
Looks at. PHY driver type (library), magnetics pin roles (centre taps).
What it catches. The PHY-side centre taps of the Ethernet transformer wired the way a different kind of PHY wants them, or only two of four taps handled on a gigabit design.
Why it matters. The two driver families need opposite things. A current-mode driver (DP83848, LAN8720A, LAN8740A) only sinks current: the line is biased from outside, through the centre tap tied to the PHY's analog supply (DP83848C §7.2, typical application: "center tap is pulled to VDD"). A voltage-mode driver (KSZ9031, DP83867) sets the common-mode voltage itself: each centre tap must go to ground through its own capacitor and to nothing else, because the four pairs can sit at different common-mode voltages depending on the link speed (KSZ9031 §12.0). Swap them and a current-mode PHY transmits nothing (no bias), while a voltage-mode PHY fights a supply on its outputs. Taps tied together on a gigabit board copied from a 10/100 one short the pairs' common modes.
Example. A design moves from a LAN8720A (10/100, current mode) to a KSZ9031 (gigabit, voltage mode) and keeps the old magnetics block: centre taps joined and fed from 3.3 V through a ferrite. Gigabit link fails or flaps; 100 Mbit/s may even come up, which hides the fault.
How to check. Classify the PHY by driver type from its library data; find the transformer's PHY-side centre tap pins (pin roles of the magnetics or magjack, NET-7); check that they are separate and capacitor-to-ground for voltage mode, or on the PHY's analog rail (NET-5) for current mode, and that all four are handled for a 1000BASE-T PHY.
Fix. Follow the PHY's datasheet: separate 100 nF per tap to ground for voltage-mode PHYs, a common tap to the analog supply with its decoupling for current-mode ones; pick magnetics with separate tap pins for gigabit.
References. KSZ9031 §12.0 (voltage-mode drivers, separate taps through 0.1 µF to ground); DP83867 §9.2.1.1 (Figure 9-2 note A: each PHY-side tap isolated, decoupled to ground); DP83848C §7.2 (typical application: centre tap pulled to VDD).