Skip to content

ETH-14 PHY multi-level strap divider computed wrongly

Severity Status Implementation
warning planned mid, depends on NET-7, IMP-6

Looks at. Strap divider values, the pin's internal pull and level table (library).

What it catches. A divider on a multi-level strap pin computed without the pin's internal pull, built with 5 % resistors, or with a capacitor straight on the strap.

Why it matters. Multi-level straps (DP83867: four levels per pin) read a voltage window, and the windows are narrow. The pin has an internal pull of its own (DP83867: 9 kΩ ±25 % to ground) in parallel with the external low-side resistor; a divider computed without it lands between two windows, and with ±25 % on the internal part the level moves across the boundary from board to board. A capacitor on the strap delays the voltage past the moment it is latched.

Example. DP83867 strap aimed at mode 3 (0.225-0.284 × VDDIO) with 10 kΩ / 3.3 kΩ, which alone gives 0.248. With the internal 9 kΩ in parallel the low side is 2.41 kΩ and the ratio 0.195: just above mode 2's 0.191 limit and below mode 3. With the internal pull at its −25 % end it reads mode 2, at +25 % it reads nothing defined. TI's table gives 5.76 kΩ / 2.49 kΩ for mode 3.

How to check. Compute each strap divider with the internal pull and its tolerance and the resistor tolerances (IMP-6 values, NET-7 for the pull and level table); every corner must stay inside one window. Flag a capacitor on the strap net.

Fix. Use the datasheet's recommended pairs with 1 % resistors, no capacitor on strap pins.

References. DP83867 §7.5.1, Table 7-5 (4-level strap ratios, 9 kΩ ±25 % internal pull-down, 1 % resistors), §6.6-6.7 (strap latch-in timing).