ETH-5 Unused pairs and centre taps without Bob Smith termination¶
| Severity | Status | Implementation |
|---|---|---|
| suggestion | planned | mid, depends on NET-7, NET-5 |
Looks at. Magjack / magnetics cable-side pins, chassis net.
What it catches. Cable-side centre taps and unused pairs (⅘ and ⅞ on 10/100) left open, or terminated wrongly: returned to signal ground instead of chassis, placed on the PHY side of the transformer, or through a capacitor rated below 2 kV.
Why it matters. The Bob Smith network (75 Ω per tap or pair into one 1 nF capacitor to chassis) gives the cable's common-mode currents a defined path to the shield and damps the resonance of unused pairs; without it they radiate and pick up noise (Ott, common-mode cable radiation). Returned to signal ground it carries that noise into the logic and defeats the transformer's isolation; a capacitor below 2 kV fails the 1500 V isolation test. TI notes it does not apply to PoE designs, where the pairs carry power.
Example. A 10/100 board with discrete Pulse H1102 magnetics: RJ45 pins ⅘ and ⅞ open, cable-side taps unconnected. It passes bring-up and fails radiated emissions around 100 MHz.
How to check. Find the magnetics' cable-side tap pins and the jack's unused pair pins (NET-7); they should reach a chassis net (NET-5, named chassis/shield) through ~75 Ω and a capacitor; flag a path to signal ground, a network on the PHY side, or a capacitor whose rating (from the value or MPN) is under 2 kV.
Fix. 75 Ω per tap and pair into a 1 nF 2 kV capacitor to chassis ground; keep chassis and circuit ground separate except at the defined tie.
References. SNLA079 §2.3 (Bob Smith: 75 Ω, 1000 pF, at least 2 kV; not for PoE), §2.4 (EMI, chassis ground); DP83867 §9.2.1.1 (Figure 9-2: 75 Ω, 1 nF 2 kV); Ott, Electromagnetic Compatibility Engineering.