ETH-8 MDI pair polarity or order against the jack¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on NET-10, NET-7 |
Looks at. PHY MDI pins, magnetics internal mapping, jack pinout.
What it catches. MDI pairs that reach the RJ45 on the wrong pins, in the wrong pair order, or with P and N swapped, after following them through the magnetics.
Why it matters. Auto MDI-X fixes the classic crossover (pairs A and B swapped), and many PHYs correct the polarity of 10BASE-T link pulses automatically, but neither covers every case: a 10/100 PHY with MDI-X disabled, a pair landing on ⅘ or ⅞, or a split pair (one pair's P and N on two different twisted pairs of the cable) does not link at all or links only on short cables. Magjacks hide the mapping inside the part, and pin-compatible looking magjacks differ.
Example. On B125A the PoE and non-PoE magjack versions turned out to have incompatible pinouts (assembly log, 22 Apr 2024): a footprint shared by two magjack MPNs only works for one of them.
How to check. Follow each PHY TX/RX pair through the transformer to the jack pins (NET-10, with the magnetics' winding map in the part data NET-7); compare to the standard pair assignment (½, 3/6, ⅘, ⅞); report pairs swapped (fine with Auto MDI-X), P/N swapped (fine only where the PHY corrects it) and split pairs (never fine).
Fix. Route pairs to the standard pins; check every alternate magjack MPN against the footprint pin by pin.
References. DP83848C §6.5.1.3.7 (automatic 10BASE-T link polarity correction); LAN8720A §3.3 (HP Auto-MDIX); Wikipedia, Medium-dependent interface "Automatic MDI-X"; B125A assembly log.