Skip to content

ETH-10 PoE PD without isolation or classification resistor

Severity Status Implementation
error planned hard, depends on NET-5, NET-7

Looks at. PD controller pins, converter topology, grounds and other ports.

What it catches. A PoE powered device whose PD side is not isolated from everything a user or another cable can touch, or whose PD controller has no classification resistor (or no detection resistor).

Why it matters. IEEE 802.3 Clause 33 keeps the cable floating: the PSE's up to 57 V and the cable pairs must stay isolated from ground and every other system potential, tested at 1500 Vac. A PD converter that ties the cable side to the board ground is only acceptable when nothing else on the board reaches the outside; with a USB port, a debug header or a metal case it makes a ground loop through the PSE or a shock path. Without the class resistor the PSE sees class 0 and budgets 13 W, or a wrong resistor claims too little power and the PSE cuts the PD under load; without the 24.9 kΩ detection signature the PSE never turns power on.

Example. A TPS2378 PD followed by a non-isolated buck on a board that also has a USB-C port and two isolated CAN channels: the USB host's ground is now tied to a PoE pair. Same board with RCLS left out: a 25 W design negotiates class 0 and the PSE allows 13 W.

How to check. Find the PD controller's CLS and DEN pins (NET-7) and their resistors to VSS / VDD; check the values against the class table. For isolation, check that the PD-side ground (NET-5) reaches the board ground only through a transformer or a rated isolation barrier, or that the board has no other external port.

Fix. RDEN 24.9 kΩ, RCLS from the class table, and an isolated converter (flyback, active clamp forward) unless the product is fully enclosed with no other port.

References. TPS2378 §7.3.3 and Table 1 (class resistor), §7.3.4 (DEN 24.9 kΩ), §7.4.1 (PoE overview, IEEE 802.3at / Clause 33), §7.4.11 (cable isolated from ground, 1500 Vac); IEEE 802.3 Clause 33; Wikipedia, Power over Ethernet.