Skip to content

SEQ-5 High voltage net without self-discharge resistors

Severity Status Implementation
warning runs in better_erc easy, depends on NET-5

Data it needs: graph, part classes, values, rails, rail voltages.

Looks at. Net voltage, capacitance, paths to ground.

What it catches. A net above a safe-to-touch voltage (above about 50 V, or a project threshold) with capacitance on it and no resistor that discharges it when the supply is removed.

Why it matters. Capacitors on a high-voltage rail stay charged for minutes or hours after unplugging: a shock or burn hazard for whoever opens the device, and an arc when a connector or probe touches it. A bleeder resistor sets a known discharge time and is required by most safety standards for exposed parts.

Example. A 48 V motor bus with 2 × 220 µF and only a gate driver's µA of quiescent current: after unplugging, the bus is still above 40 V for many minutes. A 47 kΩ bleeder brings it below 10 V in under a minute (τ ≈ 20 s) at ~50 mW in operation.

How to check. Rails with a voltage from the name or the project above the threshold (NET-5), capacitance on them, and no resistor (chain) from the rail to ground; compute the RC time constant if one exists.

Fix. A bleeder resistor (or a chain rated for the voltage), sized for the discharge time and its dissipation in operation.

References. Wikipedia, Bleeder resistor.

Settings

Set them in the project file under [checks."SEQ-5"], or for one run with --set SEQ-5.NAME=VALUE.

Setting Default Meaning
SEQ-5.min_voltage 50 V the rail voltage (magnitude) above which a net is no longer safe to touch
SEQ-5.max_chain 4 the most resistors (and LEDs) in series followed from the rail to a ground

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only SEQ-5 reports on it.

seq-5_bleeder

The test schematic seq-5_bleeder The test schematic seq-5_bleeder

  warning    SEQ-5 #5zy     +60V (60 V) has C1 and C2 (221 µF holding 0.40 J) and no resistor to discharge them when the supply is removed
                            net +60V, part C1, part C2
                            min_voltage = 50 V (derived SEQ-5 default)
                            rail voltage = 60 V (derived voltage from the net name)
                            fix: a bleeder resistor (or a chain rated for the voltage) to ground, sized for the discharge time and its dissipation in operation