Skip to content

SEQ-9 Output capacitors not discharged at power-off for a part that needs a full power-on reset

Severity Status Implementation
suggestion planned judgement, depends on NET-8

Looks at. Per-part POR requirement, rail discharge paths.

What it catches. A switched rail feeding a part that needs its supply to fall below a low voltage (often a few hundred mV) before it powers up again, with no active or resistive discharge of the rail's capacitors.

Why it matters. With the switch off and only a sleeping load, the rail decays slowly; a quick off-on (a watchdog power cycle, a user replugging) starts the part from a half-powered state where its internal POR never fired. It boots with stale registers or not at all, and the "power cycle fixes it" recovery does not.

Example. A cellular modem on a rail switched by a PMOS, 100 µF bulk, a few µA in off state: the firmware's "power cycle the modem for 100 ms" leaves the rail at 2 V, and the modem stays hung. A load switch with quick output discharge (TPS22918 QOD) pulls it to 0 V in milliseconds.

How to check. Needs the part's POR requirement from its datasheet, often only stated in prose; better_erc can list switched rails without a discharge path (QOD pin, resistor) for the reviewer.

Fix. A load switch with quick output discharge, a discharge FET driven by the inverted enable, or a resistor sized for the needed time; a long enough off time in firmware.

References. SLVA883 §3.3 (quick output discharge); TPS22918 §8.3.2 (QOD).