SEQ-6 Power switch turning hard on into a capacitive load¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on NET-10, CFG-2 |
Looks at. Power switches, their gate drive, downstream capacitance.
What it catches. A MOSFET or load switch feeding an off-board load or a hot-plug port, with nothing slowing its turn-on: gate driven straight from a GPIO or a strong pull, no gate RC, a load switch without soft start.
Why it matters. The load's capacitance charges through the switch's on-resistance only: amperes for microseconds. That current comes out of the board's own input capacitance, so the source dips and the board's own parts brown out or reset. Slow turn-on with fast turn-off is the right shape: a ramp limits inrush, a quick off still protects in a fault.
Example. On B153A the switched receptacle VBUS VBUS_SW (Q102, header pin 10) turned hard on into a B129A with more than 110 µF: the dongle's own supply dipped and the hub reset. A 10 Ω resistor in the wire cured it on the bench; rev B gets a slow turn-on with a still fast turn-off (a gate RC with a diode across the resistor, or a load switch with soft start).
How to check. For each FET or load switch whose output reaches a connector (NET-10), look at the gate network (capacitor to source, series resistor) or the load switch's soft-start pin; with downstream capacitance from the project (CFG-2), compute the inrush current.
Fix. Gate RC (Cgs plus a series resistor, a diode across the resistor for fast turn-off), a load switch with adjustable rise time, or a hot-swap controller.
References. SLVA670 §2, §4.1 (response with and without slew-rate control); SLVA716 §2.2; SLVA883 §3.1; B153 rev B change list (VBUS_SW soft start).