Skip to content

CONN-1 No protection on lines going to connectors

Severity Status Implementation
warning planned mid, depends on CFG-2, NET-2

Looks at. Connector pins, protection parts on the net (TVS, ESD array, clamp).

What it catches. A net that leaves the board through a connector pin with no protection part on it: no TVS, no ESD array, no clamp diode pair, no series element that limits a fault.

Why it matters. A connector is where the outside world touches the board: a charged person or cable (IEC 61000-4-2: 8 kV contact discharge at the top level), a cable plugged in live, a wrong cable, a short to a neighbouring supply. On-chip ESD structures are rated for handling during assembly (a few hundred volts to 2 kV HBM), not for a system-level strike; the strike either kills the pin outright or weakens it so it leaks and fails months later. The board passes every bench test and fails in the field.

Example. An STM32 UART on a 4-pin JST to an external GPS module, TX and RX wired straight from the MCU to the connector: the first touch of the cable end by a user in a dry office takes out the RX pin. On our B200A every line of J102 has a 12 V TVS and a spark gap at the connector, a 255 Ω series resistor and a 5V6 Zener behind it; that is what the check looks for.

How to check. For each connector pin, the net and the nets one series resistor or ferrite away (find_chains): is there a part of a protection class (TVS, ESD array, Zener, steering diodes) with its other end on a ground or rail? The class comes from the library or the MPN (CFG-2 maps unknown parts); grounds, shields and internal board-to-board links can be waived per connector.

Fix. A TVS or ESD array per line right at the connector, its ground short to the connector's ground or shield (SLVA680); working voltage above the signal's normal range, capacitance within what the interface allows (SSZB130 §3); a series resistor behind it for slow lines (CONN-2).

References. SSZB130 §1 (why external ESD protection), §2.1, §2.4 (IEC 61000-4-2 rating), §3 (devices per interface); SLVA680 §1, §2.1; Ott chapter 15 (§15.5 preventing ESD entry); IEC 61000-4-2.