CONN-16 Connector shell or mounting pins left floating¶
| Severity | Status | Implementation |
|---|---|---|
| warning | runs in better_erc | easy, depends on netlist |
Data it needs: graph, part classes.
Looks at. Shell / mounting pins of connectors.
What it catches. Shell, shield or mounting pins of a connector that are unconnected or on a net of their own, with no recorded decision (ground, chassis, or isolated on purpose).
Why it matters. A metal shell is the first thing an ESD strike or a cable shield touches; floating, it discharges into whatever trace is closest instead of a defined path, and a cable shield ending on it shields nothing. Some connectors also use the shell as part of a circuit: microSD sockets whose card-detect switch closes against the shell.
Example. B125's change list for rev B: the microSD card detect goes from both side pins to the shell, not to GND, so the shell has to be tied to ground for detect to read at all. USB and DE-9 shells (B135B's CAN shield) need the same decision for ESD and shielding.
How to check. Connector pins named or typed as shield, shell, mounting or MP that are unconnected or alone on their net; a waiver records "isolated on purpose".
Fix. Tie the shell straight to GND, or to the chassis net in a metal case, as grounds.enclosure states (GND-7).
References. Ott §2.15 (shield terminations), §15.7 (ESD grounding), §16.2 (PCB-to-chassis ground connection); SLVA680 §1 (chassis connection next to the TVS and the connector shield).
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only CONN-16 reports on it.
conn-16_floating_shell¶
warning CONN-16 #jw9 connector J1: J1.MP (MountPin) float: an ESD discharge on the shell finds no defined path and a cable shield ending there shields nothing
part J1, pin J1.MP
fix: tie the shell straight to GND, or to the chassis net in a metal case, as grounds.enclosure states (GND-7)
warning CONN-16 #h9k connector J3: J3.9 (SHIELD) float: an ESD discharge on the shell finds no defined path and a cable shield ending there shields nothing
part J3, pin J3.9
fix: tie the shell straight to GND, or to the chassis net in a metal case, as grounds.enclosure states (GND-7)
warning CONN-16 #yqj connector J4: J4.MP (MountPin) float: an ESD discharge on the shell finds no defined path and a cable shield ending there shields nothing
part J4, pin J4.MP
fix: tie the shell straight to GND, or to the chassis net in a metal case, as grounds.enclosure states (GND-7)
CONN-16 also fires on the test schematics of other checks: gnd-7_chassis_ground, lib-31_mount_attribute, usb-4_shield.