CONN-6 Spare pins: spread power over more pins¶
| Severity | Status | Implementation |
|---|---|---|
| suggestion | planned | mid, depends on CFG-2 |
Looks at. Unconnected connector pins, pin current rating, currents on power nets.
What it catches. A connector with unused pins while a power or ground net sits on one or two pins near (or above) their current rating.
Why it matters. Contact resistance is milliohms per pin and grows with wear and corrosion; a pin near its rating heats up, and the heat ages the contact further. A spare pin costs nothing at design time and halves the current per contact. More ground pins also lower the return impedance for all signals (CONN-10).
Example. A 0.5 mm FPC to a display module, 0.5 A per contact in its datasheet: backlight supply 1 A on two pins, its ground on two pins, and four pins left NC. Doubling both to four pins puts each contact at 0.25 A.
How to check. Connectors with unconnected pins and power or ground nets whose current (from the project, CFG-2) per pin is above a fraction of the contact rating (part data).
Fix. Give the spare pins to the power and ground nets that carry the most current; keep them evenly spread so the current shares (TE, Specifying Current).
References. TE, Specifying Current (contact temperature rise, loading density); Johnson & Graham §9.9 (power handling features of connectors).